Table 13. RECEIVER EXTERNAL PARAMETERS: Pin RX_IN, RX_OUT, REF_OUT
Parameter
Description
Condition
Min.
Max.
Unit
VOFFS_RX_IN Input offset voltage 42 dB
AGC gain = 42 dB
5
mV
VOFFS_RX_IN Input offset voltage 0 dB
AGC gain = 0 dB
50
mV
VMAX_RX_IN
Max. peak input voltage (corresponding to 62.5%
AGC gain = 0 dB
0.85
1.15
Vp
of the SD full scale)
(Note 16)
NFRX_IN
Input referred noise of the analog receiver path
AGC gain = 42 dB
(Notes 16 and 17)
150
NV/#Hz
ILE_RX_IN
IMax_REF_OUT
Input leakage current of receiver input
Max. current delivered by REF_OUT
−1
1
mA
−300
+300
mA
PSRRLPF_OUT
Power supply rejection ratio of the receiver input
AGC gain = 42 dB
10
dB
section
(Note 18)
35
(Note 19)
AGCstep
AGC gain step
5.7
6.3
dB
AGCrange
AGC range
39.9
44.1
dB
VREF_OUT
Analog ground reference output voltage
1.57
1.73
V
SNAD_OUT
Signal to noise ratio at 62.5% of the SD full scale
(Notes 16 and 20)
54
dB
VCLIP_AGC_IN
Clipping level at the output of the gain stage
1.15
1.65
Vp
16. Input at RX_IN, no other external components.
17. This parameter will be characterized on a limited number of prototypes and will not be tested in production.
18. A sinusoidal signal of 10 kHz and 100 mV ptp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT and
REF_OUT output is measured to determine the parameter.
19. A sinusoidal signal of 50 Hz and 100 mV ptp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT output is
measured to determine the parameter.
20. These parameters will be tested in production with an input signal of 95 kHz and 1 Vp by reading out the digital samples at the point AD_OUT
with the default settings of T_RX_MOD[7], SDMOD_TYP, DEC_TYP, and COR_F_ENA. The AGC gain is switched to 0 dB.
The receive LPF filter + AGC + low noise amplifier must
have a frequency characteristic between the limits listed
below. The absolute output level depends on the operating
condition. In production the measurement will be done for
relative output levels where the 0 dB reference value is
measured at 50 kHz with a signal amplitude of 100 mV.
Table 14. RECEIVER FREQUENCY
CHARACTERISTICS
Frequency (kHx)
Min. (dB)
10
−0.5
95
−1.3
130
−4.5
165
330
660
1000
2000
Max. (dB)
0.5
0.5
−2.0
−3.0
−18.0
−36.0
−50
−50
http://onsemi.com
13