Table 13. RECEIVER EXTERNAL PARAMETERS: Pin RX_IN, RX_OUT, REF_OUT
Parameter
Description
Condition
Min.
Max.
Unit
VOFFS_RX_IN Input offset voltage 42 dB
AGC gain = 42 dB
5
mV
VOFFS_RX_IN Input offset voltage 0 dB
AGC gain = 0 dB
50
mV
VMAX_RX_IN
Max. peak input voltage (corresponding to 62.5%
AGC gain = 0 dB
0.85
1.15
Vp
of the SD full scale)
(Note 16)
NFRX_IN
Input referred noise of the analog receiver path
AGC gain = 42 dB
(Notes 16 and 17)
150
NV/#Hz
ILE_RX_IN
IMax_REF_OUT
Input leakage current of receiver input
Max. current delivered by REF_OUT
â1
1
mA
â300
+300
mA
PSRRLPF_OUT
Power supply rejection ratio of the receiver input
AGC gain = 42 dB
10
dB
section
(Note 18)
35
(Note 19)
AGCstep
AGC gain step
5.7
6.3
dB
AGCrange
AGC range
39.9
44.1
dB
VREF_OUT
Analog ground reference output voltage
1.57
1.73
V
SNAD_OUT
Signal to noise ratio at 62.5% of the SD full scale
(Notes 16 and 20)
54
dB
VCLIP_AGC_IN
Clipping level at the output of the gain stage
1.15
1.65
Vp
16. Input at RX_IN, no other external components.
17. This parameter will be characterized on a limited number of prototypes and will not be tested in production.
18. A sinusoidal signal of 10 kHz and 100 mV ptp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT and
REF_OUT output is measured to determine the parameter.
19. A sinusoidal signal of 50 Hz and 100 mV ptp is injected between VDDA and VSSA. The signal level at the differential LPF_OUT output is
measured to determine the parameter.
20. These parameters will be tested in production with an input signal of 95 kHz and 1 Vp by reading out the digital samples at the point AD_OUT
with the default settings of T_RX_MOD[7], SDMOD_TYP, DEC_TYP, and COR_F_ENA. The AGC gain is switched to 0 dB.
The receive LPF filter + AGC + low noise amplifier must
have a frequency characteristic between the limits listed
below. The absolute output level depends on the operating
condition. In production the measurement will be done for
relative output levels where the 0 dB reference value is
measured at 50 kHz with a signal amplitude of 100 mV.
Table 14. RECEIVER FREQUENCY
CHARACTERISTICS
Frequency (kHx)
Min. (dB)
10
â0.5
95
â1.3
130
â4.5
165
330
660
1000
2000
Max. (dB)
0.5
0.5
â2.0
â3.0
â18.0
â36.0
â50
â50
http://onsemi.com
13
|
▷ |