English
Language : 

AMIS-30585 Datasheet, PDF (14/17 Pages) AMI SEMICONDUCTOR – S-FSK PLC Modem
AMIS−30585
Table 15. POWER−ON−RESET (POR)
Parameter
Description
VPOR
POR threshold
TRPOR
Power supply rise time
Condition
0 to 3 V
Min.
1.7
1
Max.
Unit
2.7
V
ms
Table 16. DIGITAL OUTPUTS: TDO, CLK_OUT
Parameter
Description
VOL
Low output voltage
VOH
High output voltage
Condition
IXOUT = 4 mA
IXOUT = −4 mA
Min.
Max.
Unit
0.4
V
0.85 VDD
V
Table 17. DIGITAL OUTPUTS WITH OPEN DRAIN: TX_ENB, TXD
Parameter
Description
Condition
VOL
Low output voltage
IXOUT = 4 mA
Min.
Max.
Unit
0.4
V
Table 18. DIGITAL INPUTS: BR0, BR1
Parameter
Description
VIL
Low input level
VIH
High input level
ILEAK
Input leakage current
Condition
Min.
0.8 VDD
−10
Max.
Unit
0.2 VDD
V
V
10
mA
Table 19. DIGITAL INPUTS WITH PULL DOWN: TDI, TMS, TCK, TRSTB, TEST
Parameter
Description
Condition
VIL
Low input level
VIH
High input level
RPU
Pull down resistor
(Note 21)
21. Measured around a bias point of VDD/2.
Table 20. DIGITAL SCHMITT TRIGGER INPUTS: RXC, RESB
Parameter
Description
VT+
Rising threshold level
VT−
Falling threshold level
ILEAK
Input leakage current
Condition
Min.
0.8 VDD
7
Max.
Unit
0.2 VDD
V
V
50
kW
Min.
0.9
−10
Max.
Unit
1.9
V
V
1−
uA
Table 21. DIGITAL INPUT/OUTPUTS OPEN DRAIN: IO0, IO1, IO2
Parameter
Description
Condition
VOL
Low output voltage
ICOUT = 4 mA
VIL
Low input level
VIH
High input level
ILEAK
Input leakage current
Min.
0.8 VDD
−10
Max.
Unit
0.4
V
0.2 VDD
V
V
10
mA
Table 22. CURRENT CONSUMPTION
Parameter
Description
IRX
Current consumption during receive mode
ITX
Current consumption during transmit mode
IRESET Current consumption when RESB = 0
22. CLKARM is < 12 MHz, fCLK = 24 MHz.
Condition
Current through VDD and VDDA (Note 22)
Current through VDD and VDDA (Note 22)
Current through VDD and VDAA
Typ.
60
60
Max. Unit
80
mA
80
mA
4
mA
http://onsemi.com
14