English
Language : 

E3X Datasheet, PDF (9/64 Pages) Omron Electronics LLC – Optical Fiber Photoelectric Sensor
E3X
Fine Through-beam
Model
Appearance
E32-T22S
E32-T24S
1.7 mm dia.
3.5 x 3 mm dia.
E3X
Sensing distance (standard object)*
H: 1,000 mm (1.7-mm dia. min.)
T: 650 mm (1.7-mm dia. min.)
H: 700 mm (1.7-mm dia. min.)
T: 450 mm (1.7-mm dia. min.)
Min. sensing object
(opaque objects)
H: 0.5-mm dia.
T: 0.4-mm dia.
H: 0.5-mm dia.
T: 0.4-mm dia.
Features
General purpose
Side-view
E32-T84S
H: 700 mm (1.7-mm dia. min.)
H: 0.4-mm dia.
Sensing the wafers
in cassettes (Fine,
long beam sensor
resisting 200°C)
*Use the E32-T22S and E32-T24S in combination with the E3X-H11, E3X-T11, or E3X-T21 Amplifier for stable wafer sensing.
Slot Sensors
Model
E32-G14
Appearance
*Standard object: opaque
Liquid Level Fiber Unit
Liquid Contact Model
Sensing distance (standard object)*
10 mm (slot width) (4-mm dia. min.)
Min. sensing object
(opaque objects)
T: 0.7-mm dia.
H: 1.0-mm dia.
A: 0.5-mm dia.
F: 0.6-mm dia.
V: 0.6-mm dia.
Features
Slot through-beam;
no optical axis
adjustment required
Model
E32-D82F1
E32-D82F2
Appearance
Standard
sensing object
Sensing object
angle range
Repeat
frequency
Pure water at a
temperature of
25°C.
±10° max.
0.5 mm max.
Applicable
Amplifier Unit
(see note)
E3X-NT/NM
E3X-NV
E3X-H
Note: When using the E32-D82F1 or E82-D82F2 with the E3X-A, cut the plastic fiber part to 0.5 m, otherwise the energy of the light received
by the E3X-A will be insufficient.
Pipe Mounting Model
Model
E32-L25T
Appearance
Standard sensing object
Liquid (Non-transparent liquids
may not be sensed)
Repeat frequency
1 mm max.
Applicable Amplifier Unit
E3X-NT/NM
E3X-A/H
9