English
Language : 

E3X Datasheet, PDF (39/64 Pages) Omron Electronics LLC – Optical Fiber Photoelectric Sensor
E3X
Power supply
Remote tuning input
Sensitivity setting
Maximum sensitivity
ON
OFF
H
L
T1
T2
T1
T1: 0.5 to 3 s
T2
T2: 0.5 to 1 s min.
H
L
T2: 5 s min.
Remote Bank Function
The remote bank input signal allows the setting of two kinds of sensitivity adjustment values.
Brown +V
Black; control output
Orange; self-diagnosis
input
Pink
Purple
Bank 1: SW = OFF
Bank 2: SW = ON
Blue 0 V
To set two kinds of sensitivity adjustment values, the
purple and blue wires must be connected with each oth-
er and select bank 2 to tune the E3X.
E3X
Variable Hysteresis Function (E3X-H11)
Sensing of Plate Level Differences
(If sensing is impossible with the hysteresis value set to maximum)
Reflection
of light
Reflection
of light
Large hysteresis
differential
ON
OFF
Refer to the following when using the hysteresis adjuster.
ON
OFF
Reflection
of light
Small hysteresis differential
ON
OFF
A
B
ON Unstable
Sensing operation is not stable be-
cause zone B is within the hystere-
sis differential range.
A
B
Unstable OFF
Reduce the sensitivity of the E3X with
the sensitivity adjuster and turn off
zone B.
A
B
ON
OFF
Reduce the hysteresis value with the
hysteresis adjuster so that zone A will
be ON.
339