English
Language : 

E3X Datasheet, PDF (41/64 Pages) Omron Electronics LLC – Optical Fiber Photoelectric Sensor
E3X
E3X
External Diagnostic Input Function
With this function, light projection can be stopped when desired.
The operation of the sensor can be checked with this function before
the E3X is placed into actual operation.
E3X-Ajj
Light is emitted from the projection fiber head when the self-diag-
nostic input is ON. The sensor, however, will not operate.
NPN Type
Light projection
stops
Brown (+V)
Pink
(external-
check
Input)
ON
Light
Blue (0 V)
Brown (+V)
Pink
(external-
check
Input)
E3X-Fjj/-VGjj
No light is emitted from the projection fiber head when self-diagnos-
tic input is ON.
External-diagnostic input Short
(between blue and pink) Open
LED for light projection
ON
OFF
Indicator
ON
OFF
By short-circuiting the pink and blue cords, light projection can
be stopped (with a short-circuit current of 0.2 mA max.).
OFF
Blue (0 V)
PNP Type
Light projection
stops
Light
Brown (+V)
ON
Pink
(external-
check
Input)
Blue (0 V)
Brown (+V)
OFF
Pink
(external-
check
Input)
Blue (0 V)
External-diagnostic input Short
(between brown and pink) Open
LED for light projection
ON
OFF
Indicator
ON
OFF
By short-circuiting the brown and pink cords, light projection can
be stopped (with a short-circuit current of 0.2 mA max.).
Special Fiber Units
The following special accessories are available (order separately).
Contact your OMRON representative for the details.
Fiber Units with Special Length of Stainless
Steel Tube
Fiber with different lengths of stainless steel tubes are available.
Applicable Models
E32-TC200F (tube with 0.9 dia.)
E32-TC200B/DC200F (tube with 1.2 dia.)
E32-DC200B (tube with 2.5 dia.)
Appearance
L
The length can be ordered in increments of 10 mm between
10 mm min. and 120 mm max.
Tolerance: +1.0 mm if L is 40 mm or less. and +2.0 if L is more
than 40 mm. (Note that standard Fiber Units have a 90-mm or
40-mm long stainless steel tube.)
451