K34-C1 Datasheet, PDF (7/16 Pages) Omron Electronics LLC – An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors such as Pressure, Load, Torque, and Weight Using Load Cell Signal Input.
K3HB-V
■ Power Supply Derating Curve for Sensor (Reference Value)
With 12 V
With 10 V
Max. current (mA)
Max. current (mA)
140
140
1
1
120
120
100
100
80
80
60
60
40
40
20
20
0
−20 −10 0
10 20 30 40 50 60
0
−20 −10 0
10 20 30 40 50 60
Ambient temperature (°C)
Ambient temperature (°C)
Note: 1. The above values are for standard mounting. The derating curve differs depending on the mounting conditions.
2. Do not use the Sensor outside of the derating area (i.e., do not use it in the area labeled A in the above graphics). Doing so may occa-
sionally cause deterioration or damage to internal components.
■ Component Names and Functions
Max/Min status indicator
Turns ON when the maximum value or minimum value is
displayed in the RUN level.
Level/bank display
In RUN level, displays the bank if the bank function is
ON. (Turns OFF if the bank function is OFF.)
In other levels, displays the current level.
PV display
Displays PVs, maximum values,
minimum values, parameter
names, and error names.
Position meter
Displays the position of the PV with
respect to a desired scale.
Comparative output
status indicators
Display the status of comparative outputs.
Status indicators
Display
Function
T-ZR
Zero
Turns ON when the tare zero function is
executed. Turns OFF if it is not executed or
is cleared.
Turns ON when the forced-zero function is
executed. Turns OFF if it is not executed or
is cleared. (Excluding the K3HB-H.)
Hold
Turns ON/OFF when hold input turns
ON/OFF.
HH Max
H Min
P
L
L
T-ZR CMW
LL Zero Hold
TG HH H
T LL L
MAX/MIN
LEVEL
MODE
SHIFT
UP
SV display
Displays SV and monitor values.
SV display status indicators
Display
Function
Turns ON when the timing signal turns
TG ON. Otherwise OFF.
Turns ON when parameters for which
T
teaching can be performed are
displayed.
HH, H, In RUN level, turn ON when the
L, LL
comparative set values HH, H, L, and
LL are displayed.
MAX/MIN Key
Used to switch the
display between the
PV, maximum value,
and minimum value and
to reset the maximum
and minimum values.
LEVEL Key
Used to switch level.
MODE Key
Used to switch the
parameters displayed.
SHIFT Key
Used to change
parameter settings.
When changing a set
value, this key is used
to move along the
digits.
UP Key
When changing a set value,
this key is used to change
the actual value.
When a measurement value
is displayed, this key is
used to execute or clear the
forced-zero function or to
execute teaching.