English
Language : 

K34-C1 Datasheet, PDF (5/16 Pages) Omron Electronics LLC – An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors such as Pressure, Load, Torque, and Weight Using Load Cell Signal Input.
Common Specifications
K3HB-V
■ Event Input Ratings
Input type
Contact
No-contact
S-TMR, HOLD, RESET, ZERO, BANK1, BANK2,
BANK4
ON: 1 kΩ max., OFF: 100 kΩ min.
ON residual voltage: 2 V max.
OFF leakage current: 0.1 mA max.
Load current: 4 mA max.
Maximum applied voltage: 30 VDC max.
■ Output Ratings
TIMING
---
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current: 17 mA max.
Maximum applied voltage: 30 VDC max.
Contact Output
Item
Resistive loads
(250 VAC, cosφ=1;
30 VDC, L/R=0 ms)
Rated load
5 A at 250 VAC
5 A at 30 VDC
Rated through 5A
current
Mechanical life 5,000,000 operations
expectancy
Electrical life 100,000 operations
expectancy
Inductive loads
(250 VAC, closed
circuit, cosφ=0.4;
30 VDC, L/R=7 ms)
1 A at 250 VAC
1 A at 30 VDC
Transistor Output
Maximum load voltage
Maximum load current
Leakage current
24 VDC
50 mA
100 µA max.
Linear Output
Item
Allowable load impedance
Resolution
Output error
0 to 20 mA
500 Ω max.
Approx. 10,000
±0.5%FS
4 to 20 mA
0 to 5 V
5 kΩ min.
1 to 5 V
0 to 10 V
±0.5%FS (1 V or less: no output for ±0.15 V; 0 V or less)
Serial Communications Output
Item
RS-232C, RS-485
Communications method Half duplex
Synchronization method Start-stop synchronization
Baud rate
9,600, 19,200, or 38,400 bps
Transmission code
ASCII
Data length
7 bits or 8 bits
Stop bit length
2 bits or 1 bit
Error detection
Vertical parity and FCS
Parity check
Odd, even
Note: For details on serial and DeviceNet communications, refer to
the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).
BCD Output I/O Ratings
(Input Signal Logic: Negative)
Inputs
I/O signal name
REQUEST
HOLD
MAX
MIN
RESET
Outputs DATA
POLARITY
OVER
DATA VALID
RUN
Item
Rating
Input signal
No-voltage
contact input
Input current for
no-voltage input
10 mA
Signal ON voltage 1.5 V max.
level OFF voltage 3 V min.
Maximum load
voltage
24 VDC
Maximum load
current
10 mA
Leakage current 100 µA max.
HH
H
PASS
L
LL
Maximum load
voltage
Maximum load
current
Leakage current
24 VDC
50 mA
100 µA max.
Note: For details on serial and DeviceNet communications, refer to
the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).