English
Language : 

K34-C1 Datasheet, PDF (1/16 Pages) Omron Electronics LLC – An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors such as Pressure, Load, Torque, and Weight Using Load Cell Signal Input.
Weighing Indicator
K3HB-V
CSM_K3HB-V_DS_E_8_1
An Ideal Indicator for OK/NG Judgements in Automated and
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
• Easy recognition of judgement results using color display that can be switched
between red and green. *
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimination applications.
• Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with
5-VDC power takeoff also available.)
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or 97 mm
for DeviceNet models.
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
• Capable of high-speed sampling at 50 times per second (20 ms)
• Easy-to-set two-point scaling allows conversion and display of any user-set values.
* Visual confirmation of judgement results is not supported on models that do not have an
output or models that do not support DeviceNet.
You can change the display color by setting it, but you cannot switch it based on the judgement results.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to Safety Precautions for All Digital Panel
Meters.
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
Base Units with Optional Boards
K3HB-V@
15
1. Input Sensor Code
LC: Load cell input (DC low-voltage input)
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Optional Boards
K3HB-V@-@@@
1 2 34 5
2. Sensor Power Supply/Output Type Code
None:
CPB:
L1B:
L2B:
B:
FLK1B:
FLK3B:
CPE:
L1E:
L2E:
E:
FLK1E:
FLK3E:
None
Relay output (PASS: SPDT) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 1.)
Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power
supply (10 VDC +/−5%, 100 mA) (See note 2.)
Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor
power supply (10 VDC +/−5%, 100 mA) (See note 2.)
Sensor power supply (10 VDC +/−5%, 100 mA)
Communications (RS-232C) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
Communications (RS-485) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
Relay output (PASS: SPDT) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note1.)
Linear current output (DC0(4) −20 mA) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Linear voltage output (DC0(1) −5 V, 0−10 V)+ Sensor power
supply (5 VDC +/−5%, 100 mA) (See note 2.)
Sensor power supply (5 VDC +/−5%, 100 mA)
Communications (RS-232C) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Communications RS-485) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Sensor Power Supply/Output Boards
3. Relay/Transistor Output Type Code
K33-@
None: None
C1: Relay contact (H/L: SPDT each)
2
Relay/Transistor Output Boards
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
K34-@
3
Event Input Boards
BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
* A Special BCD Output Cable (sold separately) is required.
4. Event Input Type Code
None: None
K35-@
1: 5 inputs (M3 terminal blocks), NPN open collector
2: 8 inputs (10-pin MIL connector), NPN open collector
4
3: 5 inputs (M3 terminal blocks), PNP open collector
4: 8 inputs (10-pin MIL connector), PNP open collector
Note: 1. CPB, CPE can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
Accessories (Sold Separately)
Rubber Packing
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable
Model
K32-P1
Note: Rubber packing is provided with the Controller.
1