K3NC Datasheet, PDF (20/23 Pages) Omron Electronics LLC – Up/Down Counting Meter
I Initial Settings
Power ON
I Parameters
Power ON
Press the Mode Key
Mode.
for 1 s min. to move to the Setting
Select the setup menu (
) with the Mode Key
and set the input mode, the input type, and other settings.
RUN Mode
Refer to Operation in RUN Mode.
Press the ESC Key and
Up Key for 1 s.
If required, set a prescale value in the prescaling menu
(
).
Setting Mode 1 s
Set comparative set values in the set value menu (
).
Make settings in the option menu (
) as required.
If necessary, generate simulated input for testing the output
function in output test (
).
After completing all the settings, press the ESC Key
to
return to RUN Mode.
Measurement starts.
Relationship between Input Mode and Counting Value
INA
H
L
: Up/Down B (individual inputs)
INB
H
L
Counting
value
1
00
INA
H
L
INB
H
L
Counting
value
00
3
3
2
2
2
11
: Up/Down C (phase difference inputs)
3
3
2
2
2
1
1
Note 1: The meaning of H and
L in the graphs:
Symbol
H
No-voltage
input
Closed
L
Open
2: At least 1/2 of the first
signal width is required for
B. Otherwise a counting
error of ±1 may occur.
Selecting the Sensor Type
No-contact or voltage pulse input
NO: Voltage pulse H
NC: Voltage pulse L
Contact input
Set value menu
1s
Comparative
set value bank
−
No key operation for 5 s
(See note 1.)
Comparative
set value OUT1
− 0−
No key operation for 5 s
(See note 1.)
Comparative
set value OUT2
−0−
No key operation for 5 s
(See note 1.)
Comparative
set value OUT3
−0−
No key operation for 5 s
(See note 1.)
Comparative
set value OUT4
−0−
No key operation for 5 s
(See note 1.)
Comparative
set value OUT5
−0−
No key operation for 5 s
Output test
Prescaling
The prescale function makes it possible to convert the counting value of the
K3NC into an appropriate value.
For example, the system shown in the illustration outputs 250 pulses when
the object is advanced 0.5 m. To enable the K3NC to display @@@@.@ (mm),
obtain the advanced length of the object per pulse from the following formula.
500 mm (0.5 m)/250 = 2
1. The prescale value is set by the mantissa X multiplied by the exponent Y
as follows:
Prescale value = 2.0000 x 100
X = 2.0000, Y = 00
2. Set the decimal point to the left of the rightmost digit.
0.5 m
Encoder
250 pulses
K3NC
C-150 Up/Down Counting Meter K3NC