Operating Procedures
I Operation in RUN Mode
Reset
Bank Selection
Press the RESET/TEACH Key RESET for 1 s min. to reset the counting
/TEACH
value to 0. (Enabled when key protection is cleared.)
BANK1
BANK2
RESET
Measurement
/TEACH
0
value
1 s min.
Checking the Bank Number
Press the Shift Key for 1 s min. during measurement to display
the bank number in the PV display. (The display will return to the
measurement value if there is no key operation for 5 seconds.)
COM
• Switch between the comparative set values and the prescaling val-
ues for banks 1 to 4 using the BANK 1 and BANK 2 signals.
• The relationship between the BANK 1 and BANK 2 signals and the
bank numbers is shown in the following table.
Bank
number
1
2
3
4
BANK 1
OFF
ON
OFF
ON
BANK 2
OFF
OFF
ON
ON
Comparat Prescaling
ive set
value
value
sU1.** ps1.**
sU2.** ps2.**
sU3.** ps3.**
sU4.** ps4.**
Note: If the prescale value bank is set to OFF, then the prescaling val-
ue for each bank is fixed.
Confirming and Setting Comparative Set Values
During measurement display, press the Mode Key repeatedly to display the comparative set values in the order OUT1, OUT2, OUT3, OUT4,
and OUT5. (With models that have an SV display, the comparative set values are displayed in the SV display.)
Measurement
value
Comparative set
value OUT1
Comparative set
value OUT2
Comparative set
value OUT3
Comparative set
value OUT4
Comparative set
value OUT5
No key operation for 5 s
No key operation for 5 s No key operation for 5 s
No key operation for 5 s No key operation for 5 s
Note: When a comparative set value is displayed, it can be changed using the Up Key and Shift Key (if key protection is OFF).
C-148 Up/Down Counting Meter K3NC