I Setting Procedures
The K3NC has four modes: RUN mode for normal operations, Setting mode for initial parameter input, Protect mode for lock-out configuration, and
Maintenance mode for initializing set values. The parameters that are accessible on any individual K3NC will vary depending on the Output Board
installed. Refer to the K3NC Operation Manual for details.
RUN Mode:
Remains in this mode under normal operation.
The process value can be monitored.
Using the front panel keys, the comparative set value can be changed and counting value reset can be performed.
Setting Mode:
Used for making initial settings.
Includes settings for four menus (Set value (sUset), prescaling (pscl), setup (setup), option (opt)) and the output test.
Protect Mode:
Used for locking the front key operation or parameter changes.
Maintenance Mode: Used for initializing set values.
Power ON
When power is ON
+
Maintenance mode
ESC
RUN mode
ESC
1s
ESC
Setting mode
sUset - Program set values
s.bank
sU*.01
sU*.02
sU*.03
sU*.04
sU*.05
Select bank no. of set values
Enter set value OUT1 of bank 1
Enter set value OUT2 of bank 1
Enter set value OUT3 of bank 1
Enter set value OUT4 of bank 1
Enter set value OUT5 of bank 1
Note: The above is an example when the bank number is set to 1.
pscl - Display prescaling
p.bank
ps*.ax
ps*.ay
decp.*
Select bank no. of prescale values
Set the mantissa (X) of the prescale value
Set the exponent (Y) of the prescale value
Select decimal point
Note: The above is an example when the bank number is set to 1.
setup - Program input mode/input sensor/serial communications
count
in
u-no
bps
len
sbit
prty
Specify input mode
Select a sensor type
Enter the unit no. for the host
Select the baud rate
Select the word bit length
Select the stop bits
Select the parity bits
opt - Supplementary settings related to display or control
memo
compn
con-p
out
lset.h
lset.l
r-l
Select power failure memory function
Set compensation value
Select conditions that allow compensation input
Select output mode
Enter the upper limit (H) of linear output range
Enter the lower limit (L) of linear output range
Select the remote/local programming
test - Generating simulated input for testing the output function
prot - Program lock-out configuration
all Enable all key protection
sUset Enable set value change prohibition
+ ESC
1s
Protect mode
reset
secr
Enable prohibition of counting value reset using the front
panel keys
Specify the menus to be protected against setting in the
setting mode