English
Language : 

E3X-NH Datasheet, PDF (2/40 Pages) Omron Electronics LLC – Fine Tuning Fiber Photoelectric Sensor
E3X-NH
E3X-NH
Fiber Units
Through-beam/Slot Sensors
Indicates models that allow free cutting. Models without this mark do not allow free cutting.
: E3X-NH
: E3X-NHB
Application
Features
Appearance
Sensing distance (mm) *
Standard object
(Values in parentheses: when (min. sensing
using the E39-F1 Lens Unit) object: opaque)
Model
Long distance M4
M4 screw
3 dia.
M3
2 dia.; small diameter
3-mm dia.
M3 screw
General-pur-
pose
Thin fiber
M14; with lens; ideal
for explosion-proof
applications
M4
M3; possible to
mount the reflective
side-view conversion
attachment E39-F5
M3; for detecting
minute sensing
objects
2 dia.; for detecting
minute sensing
objects
1.2 dia.; with sleeve
2-mm dia.
M4 screw
M4 screw
M3 screw
M3 screw
2-mm dia.
90 mm (40 mm) 1.2 dia.
0.9 dia.; with sleeve
Flexible (resists Possible to bend like
breaking) (R1) electric wires (R1);
M4 screw
( ): E32-TC200B4
90 mm (40 mm) 0.9 dia.
M3 screw
( ): E32-TC200F4
M4 screw
Flexible (resists Ideal for mounting
breaking) (R4); on moving sections
(R4)
M3 screw
M4 screw
90 (250)
90
700
(2,000)
1.4-mm dia.
(0.06-mm dia.)
700
0.9-mm dia.
200
(0.04-mm dia.)
55 (420)
200
14,000
2,000
400
(3,000)
10-mm dia.
(0.2-mm dia.)
1.0-mm dia.
(0.04-mm dia.)
360
55
0.5-mm dia.
100
(0.04-mm dia.)
0.5-mm dia.
100
(0.04-mm dia.)
1.0-mm dia.
400
(0.04-mm dia.)
55
0.5-mm dia.
100
(0.04-mm dia.)
280
(2,100)
1-mm dia.
(0.1-mm dia.)
0.5-mm dia.
60
(0.1-mm dia.)
1.0-mm dia.
360
(0.04-mm dia.)
50
E32-T11L
E32-T12L
E32-T21L
E32-T22L
E32-T17L
E32-TC200
E32-TC200A
E32-TC200E
E32-T22
E32-TC200B
E32-TC200B4
E32-TC200F
E32-TC200F4
E32-T11R
E32-T21R
E32-T11
M3 screw
0.5-mm dia.
E32-T21
100
(0.04-mm dia.)
Permis-
sible
bending
radius
25 mm
25 mm
25 mm
1 mm
4 mm
Side-view
Long distance;
space-saving
Suitable for
detecting minute
sensing objects
3-mm dia.
1-mm dia.
1.0-mm dia.
E32-T14L
240
(0.08-mm dia.)
30
0.5-mm dia.
E32-T24
(0.04-mm dia.)
90
Screw-mounting type
1,800
200
4.0-mm dia.
(0.08-mm dia.)
E32-T14
Note:
1. For common specifications of the Fiber Unit, refer to page 6.
2. The size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens).
3. The sensing distance of the minimum sensing object indicates the rated sensing distance unless otherwise specified.
4. Curled-cord models are also available for through-beam and reflective models.
* Sensing distance indicates values for white paper.
25 mm
2