English
Language : 

DS16EV5110 Datasheet, PDF (7/16 Pages) –
Symbol
TSU:STO
THD:DAT
TSU:DAT
TTIMEOUT
TLOW
THIGH
TLOW:SEXT
tF
tR
tPOR
Parameter
Stop Condition Setup Time
Data Hold Time
Data Setup Time
Detect Clock Low Timeout
Clock Low Period
Clock High Period
Cumulative Clock Low Extend
Time (Slave Device)
Clock/Data Fall Time
Clock/Data Rise Time
Time in which a device must be
operational after power-on reset
Conditions
(Note 12)
(Note 12)
(Note 12)
(Note 12)
(Note 12)
(Note 12)
Min
Typ
Max
Units
4.0
µS
300
nS
250
nS
25
35
mS
4.7
µS
4.0
50
µS
2
mS
300
nS
1000
nS
500
mS
Note 9: Recommended value. Parameter not tested.
Note 10: Recommended maximum capacitance load per bus segment is 400pF.
Note 11: Maximum termination voltage should be identical to the device supply voltage.
Note 12: Compliant to SMBus 2.0 physical layer specification. See System Management Bus (SMBus) Specification Version 2.0, section 3.1.1 SMBus common
AC specifications for detail.
7
www.national.com