English
Language : 

D2U5T-H3-7000-54-HU4C Datasheet, PDF (6/8 Pages) Murata Manufacturing Co., Ltd. – AC-DC Three Phase Power Converter
D2U5T-H3-7000-54-HU4C
AC-DC Three Phase Power Converter
CUSTOMER AC POWER CONNECTOR
Header
Positronic PLS5W5M1000
Position
Part Number
Function
1
Positronic: MS612N
Safety Ground
2
Positronic: MS612N-228.2
AC Line Voltage Ph 1
Contacts
3
-
Not fitted
4
Positronic: MS612N-228.2
AC Line Voltage Ph 2
5
Positronic: MS612N-228.2
AC Line Voltage Ph 3
NOTE: The Safety Ground MUST mate first. The Customer SHALL use the longer pin
specified for position 1 and the shorter pins specified for positions 2, 4 and 5.
1.795±0.020
[45.59±0.51]
3
21
5
4
0.401
[10.18]
0.802
[20.36]
1.295
[32.89]
2X Ø0.100 [Ø2.54] THRU
OUTPUT CONNECTOR
Connector: FCI Power Blade. Right Angle Header, 24 Signal Pins & 12 Power Blades. Part # 51939-486LF
Mating connector option #1: FCI Power Blade. Right Angle Connector, 24 Signal Pins & 12 Power Blades.
Part # 51915-132
Mating connector option #2: FCI Power Blade. Straight Connector, 24 Signal Pins & 12 Power Blades.
Part # 51940-323
ROWS
POWER
SIGNAL
E1 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 1 2 3 4 5 6 E2
D
C
B
PA
A
UUUUHH
PA
T T T TGG
SSSSFF
RRRRE E
www.murata-ps.com/support
D2U5T-H3-7000-54-HU4C.A02 Page 6 of 8