GENERAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Altitude (without de-rating at 40°C)
Altitude (without de-rating at 50°C)
Shock
Sinusoidal Vibration
MTBF
Weight
Safety Approvals
Input Fuses
Material Flammability
Airflow Direction
Conditions
Non-condensing
Non-condensing
3000
1800
30G non-operating
0.5G, 5 – 500 Hz
Calculated per Telcordia SR-332 @40°C
c-CSA-us (CSA 60950-1-07/UL 60950-1, Second Edition)
TÜV EN 60950-1:2006+A11+A1+A12
IEC 60950-1:2005 (2nd Ed) + A1:2009, and
EN 60950-1:2006/A11:2009/A1:2010/A12:2011
One internal 16A/500V fast blow fuse on each of the three AC line inputs
UL 94V0
From Back (connector side) to Front. Optional Front to Back.
Min
Typ
Max Units
-40
70
°C
0
50
°C
10
90
%
5
90
%
m
250K
hrs
7
kg
PROTECTION CHARACTERISTICS
Output Parameter
Over-temperature (intake)
Over Voltage
54V
Over Current Ranges 1 &2
Over Voltage
3.3VSB
Over Current
5VSB
Over Voltage
Over Current
Conditions
Auto-restart
Latching, toggling ON/OFF switch unlatches
Hiccup mode. Restart every 500msec. Recovers once load drops below OCP level
Latching, AC OFF/ON cycling required to unlatch
Constant Current Limit (Latches if Output drops below 2V). Hiccup is optional
Latching, AC OFF/ON cycling required to unlatch
Constant Current Limit (Latches if Output drops below 3V). Hiccup is optional
Min Typ Max Units
52 55 63
°C
58 60 62
V
105
130
%
3.9
4.3
V
6.3
9
A
5.6
6.0
V
4.2
6
A
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Conducted Emissions
Radiated Emissions (in the application)
ESD Immunity
Radiated Field Immunity
Electrical Fast Transients/Burst Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
Standard
IEC/EN 61000-3-2
FCC 47 CFR Parts 15
CISPR 22 EN55022
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
Voltage Dips & Interruptions
IEC/EN 61000-4-11
Voltage imbalance
(Circuit will stop when input voltage imbalance exceeds 8% for more
than 100ms. Unit will restart when imbalance returns below 8%)
Compliance
Complies
Class A, 6dB margin
Class A, 6dB margin
Level 3 criteria A
Level 3 criteria B
Level 3 criteria A
Level 3 criteria A
Level 3 criteria A
3 A/m criteria B
400Vrms Input Voltage
54V & VSB Outputs, Performance a)
100% load, Phase 0°, Dip 100% Duration 10ms
50% load, Phase 0°, Dip 100% Duration 20ms
54V & VSB Outputs, Performance b)
100% load, Phase 0°, Dip 100% Duration >10ms
Any Load, Phase 0°, Dip 100% Duration >100ms
Any valid Input Voltage, any load
54V & VSB Outputs, Performance a)
Dip 30% on single Phase or Line, Duration 100ms
54V & VSB Outputs, Performance b)
Dip 30% on single Phase or Line, Duration >100ms
www.murata-ps.com/support
D2U5T-H3-7000-54-HU4C.A02 Page 3 of 8