English
Language : 

D1U54P-W-650-12-HBXC Datasheet, PDF (5/9 Pages) Murata Power Solutions Inc. – 54mm 1U Front End AC-DC Power Supply Converter
TIMING SPECIFICATIONS
Turn-On Delay & Output Rise Time:
Power On Delay; Rise Time and Signaling
AC Input
D1U54P-W-650-12-HBxC Series
54mm 1U Front End AC-DC Power Supply Converter
AC Input
V1 PS_ON Delay
VSB
V1; 12V
VSB Power On Delay
V1 Power On Delay
PS_ON
VSB Rise
Time
V1 Rise
Time
VSB
V1; 12V
PS_ON
V1 PS_ON Delay
AC_OK
AC_OK
Delay
PW_OK
Delay
AC_OK
PW_OK
PW_OK
1. The turn-on delay after application of AC input within the operating range shall as defined in the following tables.
2. The output rise times shall be measured from 10% of the nominal output to the lower limit of the regulation band as defined in the following tables.
Time
Min
Max
Vsb Rise time
100ms
200ms
V1 Rise time
20ms
120ms
Vsb Power-on-delay
2700ms
V1 Power-on-delay
3000ms
V1 PS_ON delay
100ms
150ms
V1 PWOK delay
100ms
300ms
ACOK detect
300ms 2000ms
TIMING SPECIFICATIONS
Turn-Off (Shutdown by PS_ON)
AC Input
Turn Off Fall Time and Signaling
VSB
Turn-Off Timing
V1 Fall time
V1 PS_OFF delay
PW_OK delay off
Min
Max
-
-
0ms
5ms
1.0ms
V1; 12V
Notes
Must be monotonic
PS_ON
AC_OK
V1 PS_OFF Delay
PW_OK
V1 Falltime
PWOK delayoff
1. Note this characteristic is applicable for the main 12Vdc output shutdown from PS_ON pulled high.
www.murata-ps.com/support
D1U54P-W-650-12-HBxC.A02 Page 5 of 9