D1U54P-W-650-12-HBXC Datasheet, PDF (1/9 Pages) Murata Power Solutions Inc. – 54mm 1U Front End AC-DC Power Supply Converter | |||
|
FEATURES
ï® 650W output power
ï® 94% efï¬ciency at 50% load
ï® 12V main output
ï® 12V standby output
ï® 1U height:
ï® 2.15" x 9.0" x 1.57"
ï® 54.5mm x 228.6mm x 40mm
ï® Full digital control
ï® 21.4 Watts per cubic inch density
ï® N+1 redundancy capable, including hot plugging
ï® Active (analogue) current sharing on 12V main
output; ORING FET
ï® Overvoltage, Overcurrent, Overtemperature
protection
ï® Internal cooling fan (variable speed)
ï® PMBusâ¢/I2C interface with status indicators
ï® RoHS compliant
ï® Two Year Warranty
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at: www.murata-ps.com/en/3d/acdc.html
D1U54P-W-650-12-HBxC Series
54mm 1U Front End AC-DC Power Supply Converter
PRODUCT OVERVIEW
The D1U54P-W-650-12-HBxC series are very high efï¬ciency 650 watt power factor corrected front end supplies with a
12V main output and a 12V Standby. An active (analogue) current share characteristic is provided to allow units to
operate in parallel. The power supply may be hot plugged; recovers from overtemperature faults, and has status LEDs
on the front panel in addition to hardware signal logic and PMBus⢠status signals. The low proï¬le 1U package and
21.4W/cubic inch power density make them ideal for delivering reliable, efï¬cient power to networking equipment,
workstations, storage systems and other 12V distributed power architectures.
ORDERING GUIDE
Part Number
Murata Internal Power Output
Part Number 90 to 264Vac
D1U54P-W-650-12-HB3C
D1U54P-W-650-12-HB4C
M1877
M1876
650W
Main
Output
12Vdc
Standby
Output
12Vdc
Airï¬ow
Front to Back
Back to front
INPUT CHARACTERISTICS
Parameter
Input Source Voltage Operating Range
Input Source Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum current at Vin = 100Vac
Inrush Current
Power Factor
Efficiency (excluding fan load)
Conditions
Ramp up
Ramp down
650W
Cold start between 0 to 200msec
At 230Vac, 100% load
At 230Vac, 50% load
At 230Vac, 20% load
At 230Vac, 50% load
At 230Vac, 100% load
Min. Nom. Max. Units
90 115/230 264 Vac
47
50/60
63
Hz
74
70
84
80
Vac
10 Arms
25 Apk
0.96
0.95
90
94
%
91
OUTPUT VOLTAGE CHARACTERISTICS
Nominal
Output
Parameter
Conditions
Min. Typ. Max. Units
Voltage
Output Set Point Accuracy 50% load; Tamb =25°C 11.96 12.00 12.04 Vdc
Line and Load Regulation
Setpoint; temperature; line
and load
-1.0%
12V
Ripple Voltage & Noise1, 2 20MHz Bandwidth
+1.0
%
120 mV p-p
Output Current Range
0
54.2
A
Load Capacitance
500
4000
μF
Output Set Point Accuracy 50% load; Tamb = 25°C 11.96 12.00 12.04
12VSB Line and Load Regulation
Setpoint; temperature; line
and load
11.7
Ripple Voltage & Noise1
20MHz Bandwidth
12.3
Vdc
120 mV p-p
Output Current
0
2
A
1 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 10 μF of tantalum capacitance on each of
the power supply outputs. A short coaxial cable to the measurement âscope input, is used.
2 Measurements assume the use of the minimum load capacitance as specified for the main 12V output and a
minimum load of 5%.
Below 5% loading the overall voltage deviation shall be within ±500mV due to zero load âskipâ cycle mode of
operation.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
Test Certificate
and Test Report
D1U54P-W-650-12-HBxC.A02 Page 1 of 9
|
▷ |