English
Language : 

D1U54P-W-650-12-HBXC Datasheet, PDF (2/9 Pages) Murata Power Solutions Inc. – 54mm 1U Front End AC-DC Power Supply Converter
OUTPUT CHARACTERISTICS
Parameter
Startup Time
Transient Response
Current sharing accuracy (Main 12V output)
Hot Swap Transients
Holdup Time (Total Effective Hold Up - See Timing Waveforms)
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Altitude (without derating at 40°C)
Shock
Operational Vibration
MTBF(Target)
Safety Approvals
Input Fuse
Weight
AIRFLOW; PRESSURE VS. FLOW (PQ) CURVES
D1U54P-W-650-12-HB3C & D1U54P-W-650-12-HB4C
D1U54P-W-650-12-HBxC Series
54mm 1U Front End AC-DC Power Supply Converter
Conditions
Min.
Typ.
Max.
AC ramp up
Note: Following a “turn off” of the 12V Main
output (for any reason whatsoever) the
output shall not be allowed to “turn on”
3
again for 1sec (even if all necessary
operating conditions are met).
Main 12V, 50% load step, 1A/μs di/dt
±5
12VSB, 50% load step, 1A/μs di/dt
500
>10% load; (* percentage of full load)
±5*
±5
Full AC Input Source Range; full load
12
Units
s
%
µs
%
%
ms
ENVIRONMENTAL CHARACTERISTICS
Conditions
Min.
Typ.
Max.
Units
90V-264Vac, 650W
-40
70
°C
-5
50
Noncondensing; +45°C
5
5
90
%
95
3000
m
30G non-operating
Sine sweep; 5-200Hz, 2G;
random vibration, 5-500Hz, 1.11G
Per Telcordia SR-332 M1C1 @40°C
576K
hrs
CAN/CSA C22.2 No 60950-1-07, Am.1:2011, Am 2:2014
ANSI/UL 60950-1-2014
IEC60950-1:2005 (2nd Ed.), Am 1:2009 + Am 2:2013
EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011 +A2:2013
BSMI CNS14336-1 (099/09/30); CNS13438 ((095/06/01)
CCC GB4943.1-2011; GB9254-1-2008; GB17625, 1-2012
Power Supply has internal 12.5A/250V fast blow fuse on the AC line input
1.63 lbs (0.741 kg)
D1U54-W-650-12-HBxC P & Q CURVE
Orignal curve in Excel spreadsheet at following location: M1845_airflow_meas_01-12-2015.xlsx
250
200
150
Airflow Front to Back
100
Airflow Back to Front
50
0
0
2
4
6
8
10
PSU airflow (CFM)
Notes:
1. The above curves represent performance based upon the use of a 20mm thickness fan.
2. Curves recorded at room ambient (circa 25°C).
3. Curves generated with intermal fan running at 100% duty cycle
www.murata-ps.com/support
D1U54P-W-650-12-HBxC.A02 Page 2 of 9