HAL805 Datasheet, PDF (11/24 Pages) Micronas – Programmable Linear Hall Effect Sensor
PRELIMINARY DATA SHEET
HAL 805
Step 2: Calculation of VOQ and Sensitivity
There are two ways to calculate the values for VOQ
and Sensitivity.
Manual Calculation:
Set the system to calibration point 1 (angle 1 = −25°)
and read the register ADC-READOUT. For our exam-
ple, the result is ADC-READOUT1 = −2500.
Next, set the system to calibration point 2 (angle 2 =
25°), and read the register ADC-READOUT again. For
our example, the result is ADC-READOUT2 = +2350.
With these measurements and the targets VOUT1 =
4.5 V and VOUT2 = 0.5 V, the values for Sensitivity and
VOQ are calculated as
4.5 V − 0.5 V 2048
Sensitivity = −2500 − 2350 * 5 V = −0.3378
VOQ = 4.5 V −
−2500 * (−0.3378) * 5 V = 2.438 V
2048
Software Calibration:
Use the menu CALIBRATE from the PC software and
enter the values 4.5 V for VOUT1 and 0.5 V for VOUT2.
Set the system to calibration point 1 (angle 1 = −25°),
hit the button “Read ADC-Readout1”, set the system to
calibration point 2 (angle 2 = 25°), hit the button “Read
ADC-Readout2”, and hit the button “Calculate”. The
software will then calculate the appropriate VOQ and
Sensitivity.
This calculation has to be done individually for each
sensor. Now, write the calculated values with the “write
and store” command into the HAL 805 for program-
ming the sensor.
Step 3: Locking the Sensor
The last step is activating the LOCK function with the
“LOCK” command. The sensor is now locked and does
not respond to any programming or reading com-
mands.
Warning: This register cannot be reset!
3. Specifications
3.1. Outline Dimensions
1.5
0.3
4.06 ±0.1
x1
x2
sensitive area
y
4.05 ±0.1
0.48
0.55 1 2 3
0.36
13.0
min.
0.42
1.27 1.27
(2.54)
branded side
45°
0.8
SPGS0014-3-A/1E
Fig. 3–1:
Plastic Transistor Single Outline Package
(TO-92UT)
Weight approximately 0.14 g
Dimensions in mm
Note: A mechanical tolerance of ±50 µm applies to all
dimensions where no tolerance is explicitly given.
3.2. Dimensions of Sensitive Area
0.25 mm x 0.25 mm
3.3. Position of Sensitive Area
TO-92UT
x1 − x2/ 2 ≤ 0.2 mm
y = 1.5 mm ± 0.2 mm
Micronas
11