DSPIC30F6011_06 Datasheet, PDF (187/228 Pages) Microchip Technology – High-Performance, 16-Bit Digital Signal Controllers
dsPIC30F6011/6012/6013/6014
TABLE 23-17: INTERNAL CLOCK TIMING EXAMPLES
Note 1:
2:
3:
Assumption: Oscillator Postscaler is divide by 1.
Instruction Execution Cycle Time: TCY = 1 / MIPS.
Instruction Execution Frequency: MIPS = (FOSC * PLLx)/4 [since there are 4 Q clocks per instruction
cycle].
TABLE 23-18: AC CHARACTERISTICS: INTERNAL RC ACCURACY(2)
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature
-40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Characteristic
Min Typ Max Units
Conditions
Internal FRC Jitter @ FRC Freq. = 7.37 MHz(1)
OS62 FRC
— +0.04 +0.16 % -40°C ≤ TA ≤ +85°C VDD = 3.0-3.6V
— +0.07 +0.23 %
Internal FRC Accuracy @ FRC Freq. = 7.37 MHz(1)
-40°C ≤ TA ≤ +125°C
VDD = 4.5-5.5V
OS63 FRC
—
— +1.50 % -40°C ≤ TA ≤ +125°C VDD = 3.0-5.5V
Internal FRC Drift @ FRC Freq. = 7.37 MHz(1)
OS64
-0.7
—
0.5
% -40°C ≤ TA ≤ +85°C VDD = 3.0-3.6V
-0.7
—
0.7
% -40°C ≤ TA ≤ +125°C VDD = 3.0-3.6V
-0.7
—
0.5
% -40°C ≤ TA ≤ +85°C VDD = 4.5-5.5V
-0.7
—
0.7
% -40°C ≤ TA ≤ +125°C VDD = 4.5-5.5V
Note 1:
2:
Frequency calibrated at 7.372 MHz ±2%, 25°C and 5V. TUN <3:0> bits can be used to compensate for
temperature drift.
Overall FRC variation can be calculated by adding the absolute values of jitter, accuracy and drift percent-
ages.
TABLE 23-19: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Characteristic
Min
Typ Max Units
Conditions
LPRC @ Freq. = 512 kHz(1)
OS65
-35
—
+35
%
—
Note 1: Change of LPRC frequency as VDD changes.
© 2006 Microchip Technology Inc.