MIC3003 Datasheet, PDF (73/75 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3003
RX Power Coefficient Look-up Table (RXLUTn)
Default values
Serial address
Byte addresses
Offset coefficients are set to a default value of zero
Slope coefficients are set to a default vakue of 1.0
A6h
40 - 71 = 28h - 47h
These registers hold the receive power slope and offset coefficients used to calibrate the MIC3003’s ADC receive power result
in internal calibration mode.
These registers are non-volatile and will be maintained through power and reset cycles. A valid OEM password is required for
access to these registers.
A6 Address
40 (28h)
41 (29h)
42 (2Ah)
43 (2Bh)
44 (2Ch)
45 (2Dh)
46 (2Eh)
47 (2Fh)
68 (44h)
69 (45h)
70 (46h)
71 (47h)
Bytes
RXSLP0h
RXSLP0l
RXOFF0h
RXOFF0l
RXSLP1h
RXSLP1l
RXOFF1h
RXOFF1l
•
•
•
RXSLP7h
RXSLP7l
RXOFF7h
RXOFF7l
RX slope 0, high byte
RX slope 0, low byte
RX offset 0, high byte
RX offset 0, low byte
RX slope 1, high byte
RX slope 1, low byte
RX offset 1, high byte
RX offset 1, low byte
•
•
•
RX slope 7, high byte
RX slope 7, low byte
RX offset 7, high byte
RX offset 7, low byte
Definition
Calibration Constants (CALCOEFn)
Default values
Offset coefficients are set to a default value of zero
Slope coefficients are set to a default vakue of 1.0
Serial address
Byte addresses
A6h
74 - 87 = 4Ah - 57h
These registers hold the slope and offset coefficients used to calibrate the MIC3003’s ADC results in internal calibration mode.
Note that the temperature offset is also used in external calibration mode; but this can be disabled in OEMCFG5 (or by setting
the offset coefficient to zero).
These registers are non-volatile and will be maintained through power and reset cycles. A valid OEM password is required for
access to these registers.
November 2009
73
M9999-111209-C