English
Language : 

MIC3003 Datasheet, PDF (55/75 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3003
D[7]
reserved
read-only
Default Value
Serial address
Byte address
D[6]
reserved
read-only
D[5]
reserved
read-only
RESETOUT
D[4]
reserved
read-only
D[3]
reserved
read-only
D[2]
RESETOUT
read/write
D[1]
RESETOUT
read/write
0000 0000b = 00h
A2h
255 = FFh
D[0]
RESETOUT
read/write
Bit(s)
D[7-3]
D[2:0] RESETOUT
Function
Reserved
Controls the reset output at pin 17
(QGPO) when Reset mode is
selected (OEMCFG3-7 set to 1)
Operation
Read-only; these bits always return 00000.
By default, these three bits are 000, and the QGPO output
is undriven.
If RESET mode is selected in OEMCFG3:
When the three bits are written to 111, QGPO’s open-drain
output will be driven low for 125 μs (typical), after which
QGPO reenters the undriven state.
The RESETOUT field is cleared from 111 to 000 22.5 ms
(typical) after the deassertion edge of QGPO. Other values
of this delay may be selected in the TRSTCLR[2:0] field in
OEMCFG2.
If Reset mode in OEMCFG3 is not selected, these three
bits have no function.
November 2009
55
M9999-111209-C
hbwhelp@micrel.com or (408) 955-1690