English
Language : 

MIC3003GFL Datasheet, PDF (60/74 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibration
Micrel, Inc.
MIC3003GFL
Fault Suppression Timer (FLTTMR)
Fault Suppression Interval in Increments of 0.5 ms
D[7]
read/write
Default value
Serial address
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
0000 0000b = 00h
A6h
D[2]
read/write
D[1]
read/write
D[0]
read/write
Byte address
10 = 0Ah
Saturation faults are suppressed for a time, tFLTTMR, following laser turn-on. This avoids nuisance tripping while the APC loop
starts up. The length of this interval is (FLTTMR x 0.5 ms), typical. A value of zero will result in no fault suppression.
A valid OEM password is required for access to this register. This register is non-volatile and will be maintained through power
and reset cycles.
Fault Mask (FLTMSK)
D[7]
OEMIM
read/write
D[6]
POHE
read/write
D[5]
reserved
D[4]
reserved
D[3]
SATMSK
read/write
D[2]
TXMSK
read/write
D[1]
IAMSK
read/write
D[0]
DFMSK
read/write
Default value
0000 0000b = 00h
Serial address
A6h
Byte address
11 = 0Bh
A valid OEM password is required for access to this register. This register is non-volatile and will be maintained through power
and reset cycles.
Bit
Function
D[7]
OEMIM OEM interrupt mask
D[6]
D[5:4]
D[3]
D[2]
D[1]
D[0]
POHE OEM Power-on Hour Meter enable
D[5:4]
SATMSK
TXMSK
IAMSK
DFMSK
Reserved
APC saturation fault mask
High TX optical power fault mask
High bias current high fault mask
Diode fault mask
Operation
1 = Interrupts are masked
0 = Interrupts are enabled
This bit is similar to the IE (Global Interrupt Enable) bit in the
User Control Register. The /INT output can only be asserted
if IE is high and OEMIM is low.
1 = Power-on Hour Meter enabled
0 = Power-on Hour Meter disabled
Always write as zero; reads undefined
1 = masked; 0 = enabled
1 = masked; 0 = enabled
1 = masked; 0 = enabled
1 = masked; 0 = enabled
July 2010
60
M9999-072910-A
hbwhelp@micrel.com or (408) 955-1690