The content of the register ARC_B is shown in Table 31 below with the default values in Table 32:
ARC_B register of the MLX90132
A
Register
Bit
69 ARC_B
7:4 ModIdx(1)
3:0 Rx Gain(2)
Function
ASK Modulation Index :
Code 1 = 10%
Code 2 = 14%
Code 3 = 18%
Code 4 = 21%
Code 5 = 24%
Code 6 = 26%
Code 7 = 30%
Code 8 = 35%
Code 9 = 39%
Code A = 40%
Code B = 43%
Code C = 45%
Code D = 96%
Reception chain amplifier Gain:
Code 0 = 34dB
Code 1 = 32dB
Code 3 = 27dB
Code 7 = 20dB
Code F = 8dB
Table 31: Register ARC_B description
(1) Characterized using ISO/IEC10373-6 setup and DVK90132 antenna matching
(2) Defined by design simulations
Communication protocol
Default value
ISO/IEC14443 Type A
0xDF
ISO/IEC14443 Type B
0x20
ISO/IEC18092 (Felica)
0x50
ISO/IEC 15693 – 10%
0x53
ISO/IEC15693 – 100%
0xD3
Table 32: Default value of ARC_B per protocol (Reader mode)
7.1.2 Example how to read back WUFlags content
WUFlags byte (refer to Table 24) is automatically updated after the MLX90132 wakes-up from an Idle
command. In SPI mode, this byte is available to read in the FIFO register. In UART mode, this byte is
asynchronously sent after wake-up. In some cases, it is useful to be able to check the WUFlags separately;
the example below shows how to do it:
Read WUFlags register value
 Read the WUFlags register value:
 MLX90132 reply:
(1) XX equal the WUFlags register value
0x0803620100
0x0001XX(1)
3901090132
Rev. 009
Page 31 of 44
Jan-2014