English
Language : 

MLX90132 Datasheet, PDF (15/44 Pages) Melexis Microelectronic Systems – 13.56MHz RFID / NFC Transceiver
MLX90132
13.56MHz RFID / NFC Transceiver
Parameter list for different protocols (Reader)
Protocol
(Reader)
Code
Parameters
Byte Bit
Function
Transmission data rate
00 – 106kbps
7:6 01 – 212kbps
10 – 424kbps
11 – 847kbps
Reception data rate
0
00 – 106kbps
5:4 01 – 212kbps
10 – 424kbps
11 – 847kbps
3:1 RFU, set to ‘0’
0
0 – No CRC added
1 – CRC auto. added
ISO14443B
NFC-B
03
1 7:0 PP (max 14, i.e. 0x0E)
Examples of commands
02020301 – ISO/IEC14443B, 106kbps
transmission & reception, Frame Waiting Time
(FWT) of 302µs, CRC automatically added
020403010400 – ISO/IEC14443B, 106kbps
transmission & reception, Frame Waiting Time
(FWT) of 4.8ms, CRC automatically added
Frame Waiting Time (FWT) definition:
These 2 bytes are optional. The default value
corresponds to a FWT of 4949ms, answer to
ATTRIB.
2 7:0 MM (max 255, i.e. 0xFF)
FWT  2PP  MM1 DD 128 32 [s]
13.56
3 7:0 DD (max 127, i.e. 0x7F)
5:4 15:0 TTTT
6 7:0 YY
7 7:0 ZZ
8
7:0 NEMD
9
7:0 NEMDRES
If PP is defined, MM must be also set, but DD
still remains optional
Timing: TR0 = TTTT/13.56 us
Coded with LSB first,
default value 1023 = 0x3FF
Timing: Min_TR1 = 128 * YY / 13.56us.
Default value: 0
Timing: Max_TR1 = 128 * ZZ / 13.56us.
Default value:26 , i.e. 0x1A
Related to EMD algorithm, please refer to
chapter Electromagnetic support (EMD)
Related to EMD algorithm, please refer to
chapter Electromagnetic support (EMD)
Table 9: Parameter values for “Protocol select” command (Reader)
3901090132
Rev. 009
Page 15 of 44
Jan-2014