English
Language : 

MLX90132 Datasheet, PDF (17/44 Pages) Melexis Microelectronic Systems – 13.56MHz RFID / NFC Transceiver
MLX90132
13.56MHz RFID / NFC Transceiver
Parameter list for different protocols (TAG Emulation)
Protocol
Code
Parameters
Byte Bit
Function
Transmission data rate
7:6
00 – 106kbps
01 – 212kbps
10..11 - RFU
ISO14443A
NFC-A
12
0
Reception data rate
5:4
00 – 106kbps
01 – 212kbps
10..11 – RFU
31)
0 = Return an error, if no field
1 = Wait for field
2
RFU, set to ‘0’
1
0 = HFO
1 = ClkRec
0
RFU, set to ‘0’
Transmission data rate
00 – 106kbps
7:6 01 – 212kbps
10 – 424kbps
11 – 847kbps
ISO14443B
NFC-B
13
0
Reception data rate
00 – 106kbps
5:4 01 – 212kbps
10 – 424kbps
11 – 847kbps
31)
0 = Return an error, if no field
1 = Wait for field
2
RFU, set to ‘0’
1
0 = HFO
1 = ClkRec
0
0 – No CRC added
1 – CRC auto. added
7:4 RFU, set to ‘0’
31)
0 = Return an error, if no field
1 = Wait for field
2
RFU, set to ‘0’
ISO18092
(212,424kb) 14
0
NFC-F
1
0 = HFO
1 = ClkRec
0
0 – No CRC added
1 – CRC auto. added
Examples of commands
Comments
02021200 – TAG/Card emulation
ISO/IEC14443A,
106kbps
for
transmission & reception, return error if no
HF field detected, HFO used as master
clock
0202120A – TAG/Card emulation
ISO/IEC14443A,
106kbps
for
transmission & reception, wait for HF field,
CLKREC use as master clock
02021300 – TAG/Card emulation
ISO/IEC14443B,
106kbps
for
transmission & reception, return error if no
HF field detected, HFO use as master
clock, CRC automatically added
0202130A – TAG/Card emulation
ISO/IEC14443B,
106kbps
for
transmission & reception, wait for HF field,
CLKREC use as master clock, CRC
automatically added
02021400 – TAG/Card emulation
ISO/IEC18092, return error if no HF field
detected, HFO use as master clock, CRC
automatically added
Note that it is not necessary to select a
data-rate for ISO18092card mode, Data-
rate will be automatically detected and
adjusted during reception (application can
read this information by sending
“SubfreqRecv” command).
Table 11: Parameter values for “Protocol select” command (TAG Emulation)
1) This option will be executed only after a “listen” command has been sent. Please refer to the chapter Listen
command (0x05) for more information.
3901090132
Rev. 009
Page 17 of 44
Jan-2014