English
Language : 

8143 Datasheet, PDF (1/24 Pages) Maxwell Technologies – 12-Bit Serial Daisy Chain D/A Converter
8143
12-Bit Serial Daisy Chain D/A
Converter
Logic Diagram
FEATURES:
• Microprocessor interfacing in serially controlled systems
• Buffered digital output pin for daisy-chaining multiple DACs
• Minimizes address-decoding in multiple DAC systems -
three wire interface for any number of DACs
- One data line
- One CLK line
- One load line
• Fast interface timing reduces timing design considerations
while minimizing microprocessor wait states.
• Improved resistance to ESD
• RAD-PAK® radiation-hardened against natural space
radiation
• Total dose hardness:
- > 50 Krad (Si), depending upon space mission
• Package:
- 16 pin RAD-PAK® flat pack
• Operating temperature: -40 to 85°C
DESCRIPTION:
Maxwell Technologies’ 8143 is a 12-bit serial-input daisy-chain
CMOS digital-to-analog converter (DAC) that features serial
data input and buffered serial data output and a greater than
50 krad (Si) total dose tolerance, dependent upon space mis-
sion. It was designed for multiple serial DAC systems, where
serially daisy-chaining one DAC after another is greatly simpli-
fied. The 8143 also minimizes address decoding lines
enabling simpler logic interfacing. It allows three-wire interface
for any number of DACs: one data line, one CLK line and one
load line. Serial data in the input register (MSB first) is
sequentially clocked out to the SRO pin as the new data word
(MSB first) is simultaneously clocked in from the SRI pin. The
strobe inputs are used to clock in/out data on the rising or fall-
ing (user selected) strobe edges (STB1, STB2, STB3, STB4).
When the shift register’s data has been updated, the new data
word is transferred to the DAC register with use of LO1 and
LD2 inputs.
Maxwell Technologies' patented RAD-PAK® packaging technol-
ogy incorporates radiation shielding in the microcircuit pack-
age. It eliminates the need for box shielding while providing
the required radiation shielding for a lifetime in orbit or space
mission. In a GEO orbit, RAD-PAK provides greater than 50
krad (Si) radiation dose tolerance. This product is available
with screening up to Class S.
07.23.03 REV 3
(858) 503-3300- Fax: (858) 503-3301- www.maxwell.com
All data sheets are subject to change without notice 1
©2003 Maxwell Technologies
All rights reserved.