MAX16070 Datasheet, PDF (9/52 Pages) Maxim Integrated Products – 12-Channel/8-Channel, Flash-Configurable System Monitors with Nonvolatile Fault Registers
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
Pin Description
PIN
MAX16070 MAX16071
NAME
FUNCTION
1–5, 34, 35,
40
1–5, 36, 37,
40
MON2–MON6,
MON7, MON8,
MON1
Monitor Voltage Input 1–Monitor Voltage Input 8. Set monitor voltage range
through configuration registers. Measured value written to the ADC register
can be read back through the SMBus or JTAG interface.
6
7
8
9
10
11
12
13
14
15
16, 33
17, 18
19–24
25, 26, 27, 29
28
30
31
32
36–39
—
6
7
8
9
10
11
12
13
14
15
16, 35
—
17–22
23–28,
30, 38, 39
29
31, 32
33
34
—
—
CSP
CSM
RESET
TMS
TDI
TCK
TDO
SDA
A0
SCL
GND
GPIO7, GPIO8
Current-Sense Amplifier Positive Input. Connect CSP to the source side of the
external sense resistor.
Current-Sense Amplifier Negative Input. Connect CSM to the load side of the
external sense resistor.
Configurable Reset Output
JTAG Test Mode Select
JTAG Test Data Input
JTAG Test Clock
JTAG Test Data Output
SMBus Serial-Data Open-Drain Input/Output
Four-State SMBus Address. Address sampled upon POR.
SMBus Serial Clock Input
Ground
General-Purpose Input/Output 7 and General-Purpose Input/Output 8.
GPIO_s can be configured to act as a TTL input, a push-pull, open-drain, or
high-impedance output or a pulldown circuit during a fault event or reverse
sequencing.
GPIO1–GPIO6
General-Purpose Input/Output 1–General-Purpose Input/Output 6. GPIO_s
can be configured to act as a TTL input, a push-pull, open-drain, or high-
impedance output or a pulldown circuit during a fault event.
N.C.
No Connection. Not internally connected.
EN
DBP
VCC
ABP
MON9–
MON12
EP
Analog Enable Input. All outputs deassert when VEN is below the enable
threshold.
Digital Bypass. All push-pull outputs are referenced to DBP. Bypass DBP with
a 1FF capacitor to GND.
Device Power Supply. Connect VCC to a voltage from 2.8V to 14V. Bypass
VCC with a 10FF capacitor to GND.
Analog Bypass. Bypass ABP with a 1FF ceramic capacitor to GND.
Monitor Voltage Input 9–Monitor Voltage Input 12. Set monitor voltage range
through configuration registers. Measured value written to the ADC register
can be read back through the SMBus or JTAG interface.
Exposed Pad. Internally connected to GND. Connect to ground, but do not
use as the main ground connection.
_______________________________________________________________________________________   9