English
Language : 

MAX14827 Datasheet, PDF (9/41 Pages) Maxim Integrated Products – Integrated LED Driver
MAX14827
IO-Link Device Transceiver
AC Electrical Characteristics (continued)
(V24 = 18V to 30V, V5 = 4.5V to 5.5V, VL = 2.5V to 5.5V, VGND = 0V; REG unconnected, all logic inputs at VL or GND; TA = -40°C
to +125°C, unless otherwise noted. Typical values are at V24 = 24V, V5 = 5V, VL = 3.3V, and TA = +25°C, unless otherwise noted.)
(Note 2)
PARAMETER
SYMBOL
CONDITIONS
TAr[10] = 00
Autoretry Period
tCL_ARP
SPI/PIN = high,
ArEn = 1 (Note 4)
TAr[10] = 01
TAr[10] = 10
TAr[10] = 11
WAKE-UP DETECTION (Figure 5)
Wake-Up Input Minimum Pulse
Width
tWUMIN CL = 3nF
Wake-Up Input Maximum Pulse
Width
tWUMAX
WU Output Low Time
tWUL Valid wake-up condition on C/Q
SPI TIMING (CS/PP, CLK/TXEN/200MA,SDI,TX/NPN, SDO/RX/THSH) (Figure 6)
Maximum SPI Clock Frequency
CLK/TXEN/200MA Clock Period
CLK/TXEN/200MA Pulse-Width
High
tCH+CL
tCH
MIN TYP MAX UNITS
50
100
ms
200
500
55
66
75
µs
85
95
110
µs
100
200
300
µs
12.5
MHz
80
ns
40
ns
CLK/TXEN/200MA Pulse-Width
Low
tCL
40
ns
CS/PP Fall to CLK/TXEN/200MA
Rise Time
tCSS
20
ns
CLK/TXEN/200MA Rise to CS/
PP Rise Hold Time
tCSH
40
ns
SDI/TX/NPN Hold Time
tDH
10
ns
SDI/TX/NPN Setup Time
tDS
25
ns
Output Data Propagation Delay
tDO
SDO/RX/THSH Rise and Fall
Times
tFT
20
ns
20
ns
Minimum CS/PP Pulse
tCSW
10
ns
Note 2: All devices are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed by
design.
Note 3: Not production tested. Guaranteed by design.
Note 3: Autoretry functionality is not available in pin-mode.
www.maximintegrated.com
Maxim Integrated │  9