English
Language : 

71M6521DE Datasheet, PDF (84/107 Pages) Teridian Semiconductor Corporation – Energy Meter IC
71M6521DE/DH/FE Data Sheet
The significance of the bits in CESTATUS is shown in the table below:
CESTATUS
[bit]
Name
Description
31-29
28
27
26
25
24-0
Not Used
F0
RESERVED
SAG_B
SAG_A
Not Used
These unused bits will always be zero.
F0 is a square wave at the exact fundamental input frequency.
Normally zero. Becomes one when VB remains below SAG_THR for SAG_CNT
samples. Will not return to zero until VB rises above SAG_THR.
Normally zero. Becomes one when VA remains below SAG_THR for SAG_CNT
samples. Will not return to zero until VA rises above SAG_THR.
These unused bits will always be zero.
The CE is initialized by the MPU using CECONFIG (CESTATE.). This register contains in packed form SAG_CNT,
FREQSEL, EXT_PULSE, I0_SHUNT, I1_SHUNT, PULSE_SLOW, and PULSE_FAST.
CE
Address
0x10
Name
CECONFIG
Default
0x5020
Description
See description of CECONFIG below
The significance of the bits in CECONFIG is shown in the table below:
IA_SHUNT and/or IB_SHUNT can configure their respective current inputs to accept shunt resistor sensors. In this
case the CE provides an additional gain of 8 to the selected current input. WRATE may need to be adjusted based on
the values of IA_SHUNT and IB_SHUNT. Whenever IA_SHUNT or IB_SHUNT are set to 1, In_8 (in the equation for Kh)
is assigned a value of 8.
The CE pulse generator can be controlled by either the MPU (external) or CE (internal) variables. Control is by the
MPU if EXT_PULSE = 1. In this case, the MPU controls the pulse rate by placing values into APULSEW and APULSER.
By setting EXT_PULSE = 0, the CE controls the pulse rate based on W0SUM_X + W1SUM_X (and VAR0SUM_X +
VAR1SUM_X).
If EXT_PULSE is 1, and if EQU = 2, the pulse inputs are W0SUM_X+W1SUM_X and VAR0SUM_X+VAR1SUM_X . In this
case, creep cannot be controlled since creep is an MPU function. If EXT_PULSE = 1 and EQU = 0, the pulse inputs
are W0SUM_X if I0SQSUM_X > I1SQSUM_X, and W1SUM_X, if I1SQSUM_X > I0SQSUM_X.
Note: The 6521 Demo Code creep function halts both internal and external pulse generation.
Page: 84 of 107