English
Language : 

71M6521DE Datasheet, PDF (11/107 Pages) Teridian Semiconductor Corporation – Energy Meter IC
71M6521DE/DH/FE Data Sheet
EQU
0, 1, 2
Regular MUX Sequence
Mux State
0
1
2
3
IA
VA
IB
VB
ALT MUX Sequence
Mux State
0
1
2
3
TEMP
VA
VBAT VB
Table 1: Inputs Selected in Regular and Alternate Multiplexer Cycles
In a typical application, IA and IB are connected to current transformers that sense the current on each phase of the
line voltage. VA and VB are typically connected to voltage sensors through resistor dividers.
The multiplexer control circuit handles the setting of the multiplexer. The function of the control circuit is governed by
the I/O RAM registers MUX_ALT, MUX_DIV and EQU. MUX_DIV controls the number of samples per cycle. It can
request 2, 3, or 4 multiplexer states per cycle. Multiplexer states above 4 are reserved and must not be used. The
multiplexer always starts at the beginning of its list and proceeds until MUX_DIV states have been converted.
The MUX_ALT bit requests an alternative multiplexer frame. The bit may be asserted on any MPU cycle and may be
subsequently de-asserted on any cycle including the next one. A rising edge on MUX_ALT will cause the multiplexer
control circuit to wait until the next multiplexer cycle and implement a single alternate cycle.
The multiplexer control circuit also controls the FIR filter initiation and the chopping of the ADC reference voltage,
VREF. The multiplexer control circuit is clocked by CK32, the 32768Hz clock from the PLL block, and launches with
each new pass of the CE program.
A/D Converter (ADC)
A single delta-sigma A/D converter digitizes the voltage and current inputs to the 71M6521DE/DH/FE. The resolution
of the ADC is programmable using the FIR_LEN register as shown in the I/O RAM section. ADC resolution can be
selected to be 21 bits (FIR_LEN=0), or 22 bits (FIR_LEN=1). Conversion time is two cycles of CK32 with FIR_LEN = 0
and three cycles with FIR_LEN = 1.
In order to provide the maximum resolution, the ADC should be operated with FIR_LEN = 1. Accuracy and
timing specifications in this data sheet are based on FIR_LEN = 1.
Initiation of each ADC conversion is controlled by the multiplexer control circuit as described previously. At the end of
each ADC conversion, the FIR filter output data is stored into the CE DRAM location determined by the multiplexer
selection.
FIR Filter
The finite impulse response filter is an integral part of the ADC and it is optimized for use with the multiplexer. The
purpose of the FIR filter is to decimate the ADC output to the desired resolution. At the end of each ADC conversion,
the output data is stored into the fixed CE DRAM location determined by the multiplexer selection. FIR data is stored
LSB justified, but shifted left by nine bits.
Voltage References
The device includes an on-chip precision bandgap voltage reference that incorporates auto-zero techniques. The
reference is trimmed to minimize errors caused by component mismatch and drift. The result is a voltage output with
a predictable temperature coefficient.
The amplifier within the reference is chopper stabilized, i.e. the polarity can be switched by the MPU using the I/O
RAM register CHOP_E (0x2002[5:4]). The two bits in the CHOP_E register enable the MPU to operate the chopper
circuit in regular or inverted operation, or in “toggling” mode. When the chopper circuit is toggled in between
multiplexer cycles, DC offsets on the measured signals will automatically be averaged out.
The general topology of a chopped amplifier is given in Figure 2.
Vinp
A
B
Vinn
A
B
CROSS
+
A
G
B
-
A
B
Voutp
Voutn
Figure 2: General Topology of a Chopped Amplifier