English
Language : 

MAX14720 Datasheet, PDF (8/38 Pages) Maxim Integrated Products – Extended System Battery Use Time
MAX14720/MAX14750
Power-Management Solution
Electrical Characteristics (continued)
(VCC = VBIN = VLIN = VHVIN = VSWIN = 2.7V, TA = -40°C to +85°C, all registers in their default state, unless otherwise noted. Typical
values are at TA = +25°C.) (Note 2)
PARAMETER
Worst-Case Accuracy
of Single VCC
Measurement
SYMBOL
VCC_ACC
CONDITIONS
VCC = 1.2V
VCC = 3.6V
MIN
TYP
MAX
UNITS
-72
-100
+72
mV
+100
Worst-Case Accuracy
VCC1 – VCC2 = 100mV
-22
+22
Of Differential VCC
VCC_ACC_DIFF
%
Measurement
VCC1 – VCC2 = 1.0V
-3.5
+3.5
VCC Voltage Wait Time
Accuracy
tWAIT_ACC
10ms, 100ms, 1s programmable
tWAIT
-10
+10
%
SAR ADC VCC Voltage
Conversion Time
tCONV
Actual full VCC measurement time
is tWAIT + tCONV
120
µs
Monitor Multiplexer
SWIN To MON Switch
Resistance
RMON_SWIN
VSWIN > 1.8V, ILOAD = 2mA
80
120
Ω
SWOUT/BIN/HVIN/
HVOUT/LIN To MON
Switch Resistance
RMON_HV
Sensed pin voltage > 1.8V,
ILOAD = 500µA
400
Ω
LOUT/BOUT To MON
Switch Resistance
BBM Time
Pulldown Resistance
UVLO/POR
RMON_LV
tBBM
RMON_PD
Sensed pin voltage > 0.9V,
ILOAD = 500µA
Anytime MONCtr[2:0] changed
MONHiZ = 0
500
Ω
80
µs
100
kΩ
Input Voltage Range
VVCC
1.8
5.5
V
BIN UVLO Threshold
Rising
BIN UVLO Threshold
Falling
LIN UVLO Threshold
Rising
LIN UVLO Threshold
Falling
POR Falling
POR Rising
VTH_BIN_RISE
VTH_BIN_FALLING
VTH_LIN_RISE
VTH_LIN_FALLING
VTH_POR_FALLING
VTH_POR_RISING
Seal mode
No seal mode
Seal mode
No seal mode
1.68
1.73
1.77
V
1.66
1.71
1.75
V
1.64
1.68
1.72
V
1.62
1.66
1.7
V
0.76
1.21
V
1.55
1.66
1.77
V
1.27
1.71
V
1.58
1.69
1.8
V
www.maximintegrated.com
Maxim Integrated │  8