English
Language : 

MAX14720 Datasheet, PDF (7/38 Pages) Maxim Integrated Products – Extended System Battery Use Time
MAX14720/MAX14750
Power-Management Solution
Electrical Characteristics (continued)
(VCC = VBIN = VLIN = VHVIN = VSWIN = 2.7V, TA = -40°C to +85°C, all registers in their default state, unless otherwise noted. Typical
values are at TA = +25°C.) (Note 2)
PARAMETER
Switch Mode
Resistance
Turn-On Time
Short-Circuit Current
Limit
Thermal-Shutdown
Threshold
SYMBOL
RON_LDO
tON_LDO
ISHRT_LDO
tSHDN_LDO
CONDITIONS
VLIN = 1.8V, ILOUT = 50mA
VLIN = 1.2V, ILOUT = 5mA
ILOUT = 0mA , time from 10% to
90% of final regulation value
ILOUT = 0mA , time from 10% to
90% of VLIN, Switch mode
VLOUT = GND
VLOUT = GND, Switch mode
TJ rising
MIN
TYP
MAX
UNITS
1
Ω
3
0.95
ms
1.8
ms
380
mA
370
mA
150
°C
Thermal-Shutdown
Hysteresis
tSHDN_HYST_LDO
21
°C
Output Noise
OUTNOISE_LDO
Battery Impedance Measurement
SWOUT Allowed
Supply Range
VSWOUT
10Hz to 100kHz, VLIN = 5V,
VLOUT = 3.3V
10Hz to 100kHz, VLIN = 5V,
VLOUT = 2.5V
10Hz to 100kHz, VLIN = 5V,
VLOUT = 1.2V
10Hz to 100kHz, VLIN = 5V,
VLOUT = 0.9V
150
125
µVRMS
90
80
2
5.5
V
SWOUT UVLO
SWOUT UVLO
Hysteresis
UVLOSWOUT
UVLOHYST
Falling edge
Hysteresis
1.92
2
V
30
mV
VCC Impedance Test
Current Range
IBIM_CUR
Programmable current source with
step change of 2x
250
8000
µA
VCC Impedance Test
Current Accuracy
IBIM_ACC
VCC > 1.2V
-10
10
%
VCC Input Divider
Resistance
RVCC
VCC measure enabled
1.5
MΩ
Measurable VCC
Voltage Range
VCC_FS
Allowed VCC voltages range for
SAR ADC operation
1.2
3.6
V
VCC Voltage Resolution
LSB
VCC_LSB
10.2
mV
www.maximintegrated.com
Maxim Integrated │  7