12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Table 8. EN_OUT1–EN_OUT12 Configuration (continued)
REGISTER/
EEPROM
ADDRESS
BIT RANGE
DESCRIPTION
[0]
EN_OUT3 Configuration (MSB)—see r1Fh[7:6]
EN_OUT4 Configuration:
000 = EN_OUT4 is an open-drain active-low output
001 = EN_OUT4 is an open-drain active-high output
010 = EN_OUT4 is a push-pull active-low output
[3:1]
011 = EN_OUT4 is a push-pull active-high output
100 = EN_OUT4 is used in closed-loop tracking
101 = EN_OUT4 is configured with a charge-pump output (MON4 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
20h
EN_OUT5 Configuration:
000 = EN_OUT5 is an open-drain active-low output
001 = EN_OUT5 is an open-drain active-high output
010 = EN_OUT5 is a push-pull active low output
[6:4]
011 = EN_OUT5 is a push-pull active-high output
100 = Reserved. EN_OUT5 is not usable for closed-loop tracking.
101 = EN_OUT5 is configured with a charge-pump output (MON5 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
[7]
EN_OUT6 Configuration (LSB)—see r21h[1:0]
[1:0]
EN_OUT6 Configuration (MSBs):
000 = EN_OUT6 is an open-drain active-low output
001 = EN_OUT6 is an open-drain active-high output
010 = EN_OUT6 is a push-pull active-low output
011 = EN_OUT6 is a push-pull active-high output
100 = Reserved. EN_OUT6 is not useable for closed-loop tracking.
101 = EN_OUT6 is configured with a charge-pump output (MON6 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
EN_OUT7 Configuration:
00 = EN_OUT7 is an open-drain active-low output
21h
[3:2]
01 = EN_OUT7 is an open-drain active-high output
10 = EN_OUT7 is a push-pull active-low output
11 = EN_OUT7 is a push-pull active-high output
[5:4]
EN_OUT8 Configuration:
00 = EN_OUT8 is an open-drain active-low output
01 = EN_OUT8 is an open-drain active-high output
10 = EN_OUT8 is a push-pull active-low output
11 = EN_OUT8 is a push-pull active-high output
[7:6]
EN_OUT9 Configuration*:
00 = EN_OUT9 is an open-drain active-low output
01 = EN_OUT9 is an open-drain active-high output
10 = EN_OUT9 is a push-pull active-low output
11 = EN_OUT9 is a push-pull active-high output
______________________________________________________________________________________ 25