BIT
NAME
DESCRIPTION
C/Q Logic Level. The QLvl bit is the inverse of the logic level at C/Q. QLvl is 1 when the
D4
QLvl
C/Q input level is low (< 8V) and is 0 when the C/Q logic level is high (> 13V) (Table 3).
QLvl remains active when the C/Q receiver is disabled (RxDis = 1). QLvl does not affect
IRQ. QLvl is not changed when the Status register is read.
C/Q Fault Interrupt. The C/QFaultInt interrupt bit and C/QFault bit (in the Mode register)
D3
C/QFaultInt
are set when a short circuit or voltage fault occurs on the C/Q driver output (see the C/Q
Fault Detection section for more information). IRQ asserts when C/QFault is 1. Read the
Status register to clear the C/QFaultInt bit and deassert IRQ.
Internal 3.3V LDO (LDO33) Undervoltage Warning. Both the UV33Int interrupt bit and
the UV33En bit (in the Mode register) are set when VLDO33 falls below the 2.4V LDO33
undervoltage threshold. If UV33En is set in the Mode register, IRQ asserts low when the
D2
UV33Int
UV33Int bit is 1. Read the Status register to clear the UV33Int bit and deassert IRQ.
Set the UV33En bit to 1 in the Mode register to enable undervoltage monitoring for
UV33Int. When enabled, UV asserts high when the UV33Int bit is 1. UV deasserts when
VLDO33 rises above the LDO33 undervoltage threshold.
VCC Undervoltage Interrupt. The UV24Int interrupt bit and the UV24 bit (in the Mode
D1
UV24Int
register) are set when the VCC voltage falls below the 7.4V undervoltage threshold. IRQ
asserts low when the UV24Int bit is 1. Read the Status register to clear the UV24Int bit
and deassert IRQ. VCC undervoltage detection cannot be disabled.
Overtemperature Warning. The OTempInt interrupt bit and the OTemp bit (in the Mode
register) are set when a high-temperature condition is detected by the devices. OTemp
is set when the temperature of the die exceeds +115NC (typ). OTempInt is set and IRQ
D0
OTempInt
asserts when the OTemp bit is 1. The OTempInt bit is cleared and IRQ deasserts when
the Status register is read.
Once cleared, OTempInt is not reset if the die temperature remains above the thermal
warning threshold and does not fall below +95°C.
Table 2. DiLvl and LI Output
VDI (V)
< 5.2
>8
DiLvl BIT
0
1
LI OUTPUT
High
Low
Table 3. QLvl and RX Output
VC/Q (V)
<8
>13
QLvl BIT
1
0
RX OUTPUT
High
Low