English
Language : 

MAX1462 Datasheet, PDF (12/16 Pages) Maxim Integrated Products – Low-Voltage, Low-Power, 16-Bit Smart ADC
Low-Voltage, Low-Power,
16-Bit Smart ADC
Table 7. EEPROM Memory Map
EE Address (hex)
Contents
10 0F 0E 0D 0C 0B 0A 09 08 07 06 05 04 03 02 01
MSB
Configuration
LSB
EE Address (hex)
Contents
20 1F 1E 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11
MSB
Gain
LSB
EE Address (hex)
Contents
30 2F 2E 2D 2C 2B 2A 29 28 27 26 25 24 23 22 21
MSB
G1
LSB
EE Address (hex)
Contents
40 3F 3E 3D 3C 3B 3A 39 38 37 36 35 34 33 32 31
MSB
G2
LSB
EE Address (hex)
Contents
50 4F 4E 4D 4C 4B 4A 49 48 47 46 45 44 43 42 41
MSB
Of0
LSB
EE Address (hex)
Contents
60 5F 5E 5D 5C 5B 5A 59 58 57 56 55 54 53 52 51
MSB
Of1
LSB
EE Address (hex)
Contents
70 6F 6E 6D 6C 6B 6A 69 68 67 66 65 64 63 62 61
MSB
Of2
LSB
EE Address (hex)
Contents
00 7F 7E 7D 7C 7B 7A 79 78 77 76 75 74 73 72 71
MSB
DOFF
LSB
Table 8. Subset of DSP Instruction
INSTRUCTION
CODE (PS)
(HEX)
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
PROGRAM
COUNTER
(P)
(HEX)
66 or 6C
47
11
2E
38
03
22
56
01
3B
S REGISTER VALUE
Register 0—Configuration
Register 1—Gain
Register 2—G1
Register 3—G2
Register 4—Of0
Register 5—Of1
Register 6—Of2
Register 7—DOFF
Register 8—Temperature
Signal
Register 9—Sensor Signal
EA
65 or 6B
Register 10—Compensated
Output D
Equation (1)
DL −
DOFF =
Gain
1 +
G1TC +
G2TC2




SignalCL
+
Of0
+
Of1TC
+
Of2TC2 
where DL, DS, and DOFF are determined by the end
product specification. DL is the desired MAX1462 out-
put corresponding to the L sensor excitation; DS is the
desired MAX1462 output corresponding to the S sensor
excitation; DOFF is the desired midscale output;
SignalCL is the digitized sensor reading at temperature
C with the L sensor excitation applied; and TC is the
digitized temperature reading at temperature C.
Unstable digitized temperature readings indicate that
thermal equilibrium has not been achieved, necessitat-
ing increased soak times or a better thermal control.
Averaging many readings from the MAX1462 will help
filter out AC variations in the sensor excitation and oven
temperature.
Begin calibration by soaking the sensor and the
MAX1462 pair at the first temperature, A, and apply the
L excitation to the sensor. Start a conversion and
record the digitized temperature TA and the digitized
12 ______________________________________________________________________________________