English
Language : 

MAX15096 Datasheet, PDF (10/15 Pages) Maxim Integrated Products – Integrated Hot-Swap/Electronic
MAX15096/MAX15096A/
MAX15096D
2.7V to 18V, 6A Integrated Hot-Swap/
Electronic Circuit Breaker
Detailed Description
Enable Logic and Undervoltage/
Overvoltage-Lockout Threshold
The supply output can become active only after all the
following events have occurred:
● IN is within the UVOV window
● VCC is above its UVLO threshold
● EN meets its enable threshold for more than 100μs
● PRSNT is low for more than 400µs
The MAX15096 devices enable the outputs as shown in
Table 1. The devices are ready to drive the output when
the VCC supply rises above the VUVLO threshold. The
devices turn on the output when VCC > VUVLO, VUVOV
is higher than 0.55V (VUV_TH) and less than 1.23V
(VOV_TH). The devices turn off the output when VUVOV
falls below (0.55V - VUV_HYS) or VUVOV rises above
1.23V. An external resistive divider from IN to UVOV and
ground provide the flexibility to select the undervoltage/
overvoltage-lockout threshold to the desired value. See
Figure 1 and the Setting the Undervoltage/Overvoltage
Threshold section in the Applications Information section.
Startup
Once the devices’ output is enabled, the device pro-
vides controlled application of power to the load. The
voltage at OUT begins to rise at approximately 10V/ms
default until the programmed circuit-breaker current level
is reached, while the devices actively limit the inrush
current at the circuit-breaker setting.An external capacitance
connected to the GATE pin allows the user to program
the slew rate to a value lower than the default. The inrush
current can be programmed by appropriate selection of
RCB. During startup, a foldback current limit is active
to protect the internal MOSFET to operate within safe
operating area. (Figure 2).
Table 2. Output Enable Truth Table
POWER SUPPLY
VCC UVLO
VCC > VUVLO
VCC < VUVLO
X
X
X = Don’t care.
VUV_TH = 0.55V (typ).
VOV_TH = 1.23V (typ).
PRECISION ANALOG INPUT
UVP
OVP
VUVOV > VUV_TH
X
VUVOV < VOV_TH
X
VUVOV < (VUV_TH - VUV_HYS)
X
X
VUVOV > VOV_TH
OUT
On
Off
Off
Off
IN
R1
REF1
UVOV
R2
MAX15096
MAX15096A
MAX15096D
CONTROL
LOGIC
GND REF2
Figure 1. Undervoltage/Overvoltage Threshold Setting
IINRUSH
3A
RCB = 42.1kΩ
0.64A
0.5A
0.1A
RCB = 10.5kΩ
2V
10V
VIN - VOUT
Figure 2. Startup Inrush Current Foldback Characteristics
www.maximintegrated.com
Maxim Integrated │  10