English
Language : 

28953-DSH-001-A Datasheet, PDF (158/173 Pages) M/A-COM Technology Solutions, Inc. – HDSL Channel Unit
6.0 Electrical and Timing Specifications
6.1 Absolute Maximum Ratings
Table 6-5. Data Timing Requirements
Symbol
Parameter
Ts Input Setup Time
Thld Input Hold Time
RS8953B/8953SPB
HDSL Channel Unit
Minimum
35
10
Maximum
Units
ns
ns
Table 6-6. Input Clock Edge Selection
Clock
Edge
Inputs
BCLK1
BCLK2
BCLK3
TCLK
TCLK
RCLK
RCLK
EXCLK
EXCLK
EXCLK
EXCLK
TCK
Falling
Falling
Falling
Falling
Rising
Falling
Rising
Falling
Rising
Falling
Rising
Rising
HDSL Channel Inputs
QCLK1, RDAT1, TAUX1
QCLK2, RDAT2, TAUX2
QCLK3, RDAT3, TAUX3
PCM Channel Inputs
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
TSER, INSDAT, TMSYNC
Test Access Inputs
TMS, TDI
TCLK_SEL RCLK_SEL RCLK_INV
(CMD_2) (CMD_2) (CMD_7)
—
00
—
—
01
—
—
1x
00
0
1x
00
1
1x
01
0
1x
01
1
1x
10
0
1x
10
1
—
6-4
Conexant
N8953BDSB