LTC4012-3_15 Datasheet, PDF (6/28 Pages) Linear Technology – High Efficiency, Multi-Chemistry Battery Charger with PowerPath Control | |||
|
◁ |
LTC4012-3
Typical Performance Characteristics
(TA = 25°C unless otherwise noted. L = IHLP-2525 6.8µH)
Charge Current Accuracy
2
1
0
â1
DCIN = 24V
RPROG = 35.7k
â2
DCIN = 12V
RPROG = 26.7k
â3
â4
â5
RSENSE = 33mΩ
RIN = 3.01k
â6
0 2 4 6 8 10 12 14 16 18 20 22 24
BAT (V)
4012-3 G07
Charge Current Line Regulation
0.5
BAT = 6V
0.4 RSENSE = 33mΩ
0.3 RIN = 3.01k
0.2
ICHG = 1A
0.1
0
ICHG = 2A
â0.1
â0.2
ICHG = 3A
â0.3
â0.4
â0.5
5
10
15
20
25
DCIN (V)
4012-3 G08
Charge Current Load Regulation
3.5
ICHG = 3A
3.0
2.5
ICHG = 2A
2.0
1.5
ICHG = 1A
1.0
0.5
DCIN = 20V
0 RSENSE = 33mΩ
â0.5 RIN = 3.01k
11.0 11.4 11.8 12.2
BAT (V)
12.6 13.0
4012-3 G09
Input Current Limit
3.0
2.5
IIN
2.0
1.5
ICHG
1.0
0.5 2.5A BULK CHARGE
2.1A INPUT CURRENT LIMIT
0
â0.5
â1.0
0
ICL STATE
0.5
1.0
1.5
2.0 2.5
SYSTEM LOAD (A)
4012-3 G10
PWM Soft-Start
ICHG
2A/DIV
ITH
1V/DIV
PROG
1V/DIV
SHDN
5V/DIV
TIME (500µs/DIV)
4012-3 G11
Gate Drive Non-Overlap
BGATE
TGATE
TIME (80ns/DIV)
4012-3 G12
40123fb
|
▷ |