English
Language : 

PDT006A0X3-SRZ Datasheet, PDF (33/39 Pages) Lineage Power Corporation – 6A Digital Pico DLynxTM: Non-Isolated DC-DC Power Modules 3Vdc ––14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A Output Current
Preliminary Data Sheet
October 17, 2011
6A Digital Pico DLynxTM: Non-isolated DC-DC Power Modules
3 –– 14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A output current
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 49. The preferred airflow direction
for the module is in Figure 50.
Wind Tunnel
PWBs
25.4_
(1.0)
Power Module
The thermal reference points, Tref used in the
specifications are also shown in Figure 50. For reliable
operation the temperatures at these points should not
exceed TBD. The output power of the module should
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note ““Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules”” for a detailed discussion of
thermal aspects including maximum device
temperatures.
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Figure 49. Thermal Test Setup.
Figure 50. Preferred airflow direction and location
of hot-spot of the module (Tref).
LINEAGE POWER
33