English
Language : 

PDT006A0X3-SRZ Datasheet, PDF (27/39 Pages) Lineage Power Corporation – 6A Digital Pico DLynxTM: Non-Isolated DC-DC Power Modules 3Vdc ––14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A Output Current
Preliminary Data Sheet
October 17, 2011
6A Digital Pico DLynxTM: Non-isolated DC-DC Power Modules
3 –– 14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A output current
Table 6 (continued)
Hex
Code
36
38
Command
VIN_OFF
IOUT_CAL_GAIN
Brief Description
Sets the value of input voltage at which the module turns off
Format
Linear, two’’s complement binary
Bit Position
7
6
5
4
3
2
1
0
Access
r
r
r
r
r
r
r
r
Function
Exponent
Mantissa
Default Value 1
1
1
1
0
0
0
0
Bit Position
7
6
5
4
3
2
1
0
Access
r r/w r/w r/w r/w r/w r/w r/w
Function
Mantissa
Default Value 0
0
0
0
1
0
1
0
Returns the value of the gain correction term used to correct the measured
output current
Format
Linear, two’’s complement binary
Bit Position
7
6
5
4
3
2
1
0
Access
r
r
r
r
r
r
r r/w
Function
Exponent
Mantissa
Default Value 1
0
0
0
1
0
0
V
Bit Position
7
6
5
4
3
2
1
0
Access
r/w r/w r/w r/w r/w r/w r/w r/w
Function
Mantissa
Default Value
V: Variable based on factory calibration
Non-Volatile
Memory
Storage
YES
YES
Returns the value of the offset correction term used to correct the measured
output current
Format
Linear, two’’s complement binary
Bit Position
7
6
5
4
3
2
1
0
Access
r
r
r
r
r r/w r
r
39
IOUT_CAL_OFFSET
Function
Exponent
Mantissa
YES
Default Value 1
1
1
0
0
V
0
0
Bit Position
7
6
5
4
3
2
1
0
Access
r
r r/w r/w r/w r/w r/w r/w
Function
Mantissa
Default Value 0
0 V: Variable based on factory calibration
Sets the voltage level for an output overvoltage fault
Format
Linear, two’’s complement binary
Bit Position
7
6
5
4
3
2
1
0
Access
r r/w r/w r/w r/w r/w r/w r/w
40
VOUT_OV_FAULT_LIMIT
Function
High Byte
Default Value 0
0
0
0
0
1
0
1
Bit Position
7
6
5
4
3
2
1
0
Access
r/w r/w r/w r/w r/w r/w r/w r/w
Function
Low Byte
Default Value 0
0
0
0
1
0
1
0
YES
Instructs the module on what action to take in response to a output
overvoltage fault
Format
Unsigned Binary
41 VOUT_OV_FAULT_RESPONSE
Bit Position
Access
7
6
5
4
3
r/w r/w r/w r/w r/w
2
r
1
r
0
r
Function
RSP
[1]
RSP
[0]
RS[2] RS[1] RS[0]
X
X
X
Default Value 1
1
1
1
1
1
0
0
YES
LINEAGE POWER
27