07 | Keysight | E6706G 1xEV-DO Lab Application - Technical Overview
Technical Specifications
These specifications apply to the E5515E, or E5515C mainframe with Option 003
installed, when used with the latest shipping version of the E6706G lab application.
These applications also include functionality described within the E1966A 1xEV-DO test
application data sheet. For details visit www.keysight.com/find/E1966A.
Specifications describe the test set’s warranted performance and are valid over the
entire operation and environmental ranges unless otherwise noted. All specifications are
valid after a 30-minute warm-up period of continuous operation.
Supplemental characteristics are intended to provide additional information useful in
applying the instrument by giving typical, but non-warranted performance parameters.
These characteristics are shown in italics and labeled as typical. All units shipped from
the factory meet these typical numbers at 25 °C ambient without including measurement
uncertainty.
Additionally, these specifications also apply to an E5515C/E mainframe with Option 003
running the latest shipping version of the E6706U lab application over the 25 °C ±5 °C
ambient temperature range. The E6706U operating conditions are 0 to 35 °C.
1xEV-DO call processing functionality
Resident formats
Call processing timing tolerance
Overhead messages
Protocol stack
Base station parameters
Enhanced idle state protocol
R-DRC fixed mode attribute
1xEV-DO
Mobile transmissions must be typically within ±6 µs of test
set’s transmitted pilot channel clock timing for proper reverse
channel acquisition
Sync message with real-time long code and system time
update, quick configuration message, sector parameters
message, and access parameters message
1xEV-DO Release 0, Release A, or Release B using test
application protocol (TAP/FTAP/RTAP, ETAP/FETAP/RETAP,
or MCTAP/FMCTAP/RMCTAP, respectively), default packet
application protocol for Release 0 and Release A, and Multi-
Flow Packet Application for Release A
ACK channel gain, DRC channel gain, data offset nom, data
offset 9k6, data offset 19k2, data offset 38k4, data offset 76k8,
and data offset 153k6
Supports user-settable slot cycles to be set ranging from
0.1066 to 40.96 seconds
On or Off. Default of On. When in the On state, the test set
transmits the user-set forward traffic rate. When in the off
state, the test set transmits the forward configuration per the
received DRC value transmitted by the AT