English
Language : 

N1045A Datasheet, PDF (31/37 Pages) Keysight Technologies – Wide-Bandwidth Oscilloscope Mainframe and Modules
31 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet
Ordering Information
86100D
Infiniium DCA-X mainframe
86100D
Hardware options
86100D-STR Standard trigger
86100D-ETR Enhanced trigger
86100DU-ETR Enhanced trigger upgrade kit
86100D-PTB Precision timebase integrated in the mainframe
86100DU-PTB Upgrade mainframe with integrated precision timebase
86100D-GPI GPIB card interface installed (default)
86100D-GPN No GPIB card interface
86100D-090 Removable hard drive
86100D-092 Internal hard drive (default)
86100D software options
86100D-xxx Are permanent fixed-node licenses installed by the
factory
86100DU-xxx Are permanent fixed-node licenses installed by the
customer (software upgrades)
86100DT-xxx Are permanent transportable licenses installed by the
customer
The “-xxx” option code provides the same functionality independent of the
prefix (i.e., 86100D or 86100DU or 86100DT)
86100D-BFP Automatic fixture removal
86100D-061 MATLAB - Basic Oscilloscope package
86100D-062 MATLAB - Standard Oscilloscope package
86100D-200 Enhanced jitter analysis software
86100D-201 Advanced waveform analysis software
86100D-202 Enhanced impedance and S-parameter software
86100D-300 Amplitude analysis/RIN/Q-factor
86100DU-400 PLL and jitter spectrum software 1
86100D-401 Advanced EYE analysis software 1
86100D-SIM InfiniiSim-DCA software
86100D-500 Productivity package software
86100D-9FP PAM-N analysis software, fixed perpetual license
N1012A
OIF CEI compliance and debug application
N1014A
SFF-8431 compliance and debug application
N1019A
User-defined application
N1081A
IEEE 802.3 KR/KR4 application
N1082A
IEEE 802.3bj XLAUI, CAUI-10 and nPPI; IEEE 802.3bm
CAUI-4 (Option -4TP)
N1083A
IEEE 802.3 40GBASE-CR4 and 100GBASE-CR10
N1084A
IEEE802.3 KR4/CR4 application
Misc options
86100D-AFP Module slot filler panel
86100D-AX4 Rack mount flange kit
86100D-AXE Rack mount flange kit with handles
86100D-UK6 Commercial cal certificate with test data
86100DU-WN7 Upgrade to Windows 7 operating system
Note:
–– Option BFP requires Option 202.
–– For complete PAM4 analysis capability, Option 9FP requires Options
200/201/300/401.
–– Options 200, 201, and SIM require Option ETR (enhanced trigger).
–– Option 300 requires Options 200 and ETR.
–– Option 400 requires Microsoft Office Excel 2007/2010.
Optical/electrical modules
86105C
9 GHz optical channel; single-mode and multimode,
amplified (750 to 1650 nm) 20 GHz electrical channel
86105C-100 155 Mb/s through 8.5 Gb/s (choose 4 filter rates from
Options 86105C-110 through 86105C-195)
86105C-110 155 Mb/s
86105C-120 622 Mb/s (also covers 614 Mb/s)
86105C-130 1.063 Gb/s
86105C-140 1.244/1.250 Gb/s (also covers 1.229 Mb/s)
Optical/electrical modules (Continued)
86105C-150 2.125 Gb/s
86105C-160 2.488/2.500 Gb/s (also covers 2.458 Gb/s)
86105C-170 2.666 Gb/s
86105C-180 3.125 Gb/s (also covers 3.072 Gb/s)
86105C-190 4.250 Gb/s
86105C-193 5.0 Gb/s
86105C-195 6.250 Gb/s (also covers 6.144 Gb/s)
86105C-200 8.5, 9.953, 10.3125, 10.519, 10.664, 10.709, 11.096,
11.317 Gb/s
86105C-300 Combination of rates available in 86105C-100 and
86105C-200
86105D2
20 GHz optical channel; single-mode and multimode,
(750 to 1650 nm); filters for 8.5, 9.953, 10.3125, 10.519,
10.664, 10.709, 11.096, 11.317, 14.025 Gb/s; 35 GHz
electrical channel
86105D-100 Identical capability as 86105D, 14.025 Gb/s filter not
included
86105D-200 Identical capability as 86105D, only filter provided is
14.025 Gb/s
86105D-IRC 3 System impulse response correction calibration
86105D-281 34 GHz optical channel, filters for 15, 25.78 , 27.95, 28.05
Gb/s (contact Keysight for additional 14.025 Gb/s filter) 4.
50 GHz electrical channel
86115D 2
20 GHz multi-optical port plug-in module; single-mode and
multimode (750 to 1650 nm); filters for 8.5, 9.953, 10.3125,
10.519, 10.664, 10.709, 11.096, 11.317, 14.025 Gb/s
86115D-002 Two optical channels with filters for all rates listed (8.5 to
14.025 Gb/s)
86115D-102 Identical capability as 86115D-002, 14.025 Gb/s filters not
included
86115D-142 Identical capability as 86115D-002, only filters provided
are 14.025 Gb/s
86115D-282 Two optical channels with filters for 15, 25.78, 27.95, 28.05
Gb/s (contact Keysight for 14.025 Gb/s filter) 4
86115D-004 Four optical ports with filters for all rates listed (8.5 to
14.025 Gb/s) mulitplexed to two optical channels through 2
integral 1X2 optical switches
86115D-104 Identical capability as 86115D-004, 14.025 Gb/s filters not
included
86115D-144 Identical capability as 86115D-004, only filters provided
are 14.025 Gb/s
86115D-IRC System impulse response correction calibration
86116C 2
40 to 65 GHz optical/80 GHz electrical sampling module,
1300 to 1620 nm
86116C-IRC 3 System impulse response correction calibration
This module is not compatible with the 86100A and 86100B DCA
mainframes. If you want to upgrade older DCAs, contact Keysight
Technologies to discuss current trade-in deals. All optical modules have
FC/PC connectors installed on each optical port. Other connector adapters
available as options are: Diamond HMS-10, DIN, ST and SC.
1.  Fixed node customer installed or transportable customer installed
(86100DU or 86100DT). Not available as a factory-installed license.
2.  This module is not compatible with the 86100A and 86100B DCA
mainframes. If you want to upgrade older DCAs, contact Keysight
Technologies to discuss current trade-in deals.
3.  System impulse response correction calibration provides a unique
calibration file for the optical channel(s). The FlexDCA user interface uses
this calibration file to create ideal reference receiver responses for more
accurate and consistent transceiver compliance testing. IRC also allows
reference receivers to be defined at any data rate within ± 50% of the
hardware response. This allows optical receivers to significantly extend
their operating range.
4.  A 15 Gb/s filter is provided with Option 281 and 282 that closely
approximates the response required for 16X Fibre Channel compliance
testing. Contact Keysight for a special option that verifies compliance
of the 86105D-281 and 86115D-282 to the 16X Fibre Channel reference
receiver specification.