18 | Keysight | Inï¬niiVision 2000 X-Series Oscilloscopes - Data Sheet
Performance Characteristics (Continued)
WaveGen â built-in function generator (Specifications are typical)
Waveforms
Sine, square, pulse, triangle, ramp, noise, DC
Sine
ââ Frequency range: 0.1 Hz to 20 MHz
ââ Amplitude flatness: ± 0.5 dB (relative to 1 kHz)
ââ Harmonic distortion: â40 dBc
ââ Spurious (non harmonics): â40 dBc
ââ Total harmonic distortion: 1%
ââ SNR (50 ⦠load, 500 MHz BW): 40 dB (Vpp ⥠0.1 V); 30 dB (Vpp <0.1 V)
Square wave/pulse
ââ Frequency range: 0.1 Hz to 10 MHz
ââ Duty cycle: 20 to 80%
ââ Duty cycle resolution: Larger of 1% or 10 ns
ââ Pulse width: 20 ns minimum
ââ Pulse width resolution: 10 ns or 5 digits, whichever is larger
ââ Rise/fall time: 18 ns (10 to 90%)
ââ Overshoot: < 2%
ââ Asymmetry (at 50% DC): ± 1% ± 5 ns
ââ Jitter (TIE RMS): 500 ps
Ramp/triangle wave
ââ Frequency range: 0.1 Hz to 100 kHz
ââ Linearity: 1%
ââ Variable symmetry: 0 to 100%
ââ Symmetry resolution: 1%
Noise
Bandwidth: 20 MHz typical
Frequency
ââ Sine wave and ramp accuracy:
ââ 130 ppm (frequency < 10 kHz)
ââ 50 ppm (frequency > 10 kHz)
ââ Square wave and pulse accuracy:
ââ [50+frequency/200] ppm (frequency < 25 kHz)
ââ 50 ppm (frequency ⥠25 kHz)
ââ Resolution: 0.1 Hz or 4 digits, whichever is larger
Amplitude
ââ Range:
ââ 20 mVpp to 5 Vpp into Hi-Z
ââ 10 mVpp to 2.5 Vpp into 50 â¦
ââ Resolution: 100 µV or 3 digits, whichever is larger
ââ Accuracy: 2% (frequency = 1 kHz)
DC offset
ââ Range:
ââ ± 2.5 V into Hi-Z
ââ ± 1.25 V into 50 ohms
ââ Resolution: 100 μV or 3 digits, whichever is larger
ââ Accuracy: ± 1.5% of offset setting ± 1.5% of amplitude ± 1 mV
Trigger output
Trigger output available on Trig out BNC
|
▷ |