English
Language : 

E6704A Datasheet, PDF (10/15 Pages) Keysight Technologies – E6702G cdma2000/IS-95/AMPS
10 | Keysight | E6702F cdma2000/IS-95/AMPS Lab Application - Technical Overview
Trigger functionality
Logging triggers
Trigger start and stop criteria
Trigger types
Event trigger
Message match parameters
Time trigger
Trigger counts
Log filter functionality
Log filter
Filter types
Event filter
Message match parameters
Time filter
Selectable start logging trigger and stop logging trigger; defined
triggers may be saved and recalled
Start and stop triggers can be configured to pre-capture or post-
capture a specific number of messages; stop trigger can also be
defined as a time duration after the start trigger occurred
Event, message match, time, and trigger counts
Message dropped, received message, and received message
overflow
Triggers can be defined as any fields, not a match to, or any specific
values for the following parameters:
–– F-csch (f-synch) MSG_TYPE
–– F-csch MSG_TYPE
–– CONFIG_MSG_SEQ
–– ACC_MSG_SEQ
–– F-csch/f-dsch ORDER
–– ORDQ
–– PAGE_CLASS
–– MSG_ID
–– R-csch/r-dsch ORDER
–– F-dsch MSG_TYPE
–– R-dsch MSG_TYPE
–– Paging indicator 1
–– Paging indicator 2
Definable start trigger on specific timestamp and day based on PC
real-time clock
Specified number of start trigger occurrences before log capture
begins
Definable filter for data is captured into the log file; defined filters
may be saved and recalled
Event, message match, and time
Message received
Filters can be defined as any fields, not a match to, or any specific
values for the following parameters:
–– F-csch (f-synch) MSG_TYPE
–– F-csch MSG_TYPE
–– CONFIG_MSG_SEQ
–– ACC_MSG_SEQ
–– F-csch/f-dsch ORDER
–– ORDQ
–– PAGE_CLASS
–– MSG_ID
–– R-csch/r-dsch ORDER
–– F-dsch MSG_TYPE
–– R-dsch MSG_TYPE
–– Paging indicator 1
–– Paging indicator 2
Allows events to pass through if timestamp is after specified time,
before specified time, or between specified start and stop time