ISL78220
Electrical Specifications Operating Conditions: VIN = 12V, TA = -40°C to +125°C, unless otherwise specified. Typical specifications
are at TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to +125°C. (Continued) (Continued)
PARAMETER
TEST CONDITIONS
MIN
MAX
(Note 6) TYP (Note 6) UNITS
Maximum Voltage Limit at IOUT Pin
2.0
V
DMAX PIN
DMAX Threshold, High
3
V
DMAX Threshold, Low
2
V
DMAX Floating Voltage
During Phase Detection Time (t3 on Figure 14)
Max Duty Cycle, DMAX = GND
VCOMP = 3.5V
Max Duty Cycle, DMAX = FLOAT
VCOMP = 3.5V
Max Duty Cycle, DMAX = VCC
VCOMP = 3.5V
DMAX Source/Sink Current
During t3 on Figure 14
DMAX Source/Sink Current
After t3 on Figure 14
PWM_TRI, PWM_INV, SYNC PIN DIGITAL LOGIC
2.5
V
91.7
%
75
%
83.3
%
50
µA
-1
1
µA
Input Leakage Current
EN < 1V
-1
1
µA
Input Pull Down Current
EN > 2V, Pin Voltage = 2.1V
0.4
1.5 µA
Logic Input Low
0.8
V
Logic Input High
2
V
DRIVE_EN, CLK_OUT PIN
Output High Voltage
Output Low Voltage
VOUT SENSE PIN
IDRIVE_EN = 500µA
IDRIVE_EN = -500µA
4.5
V
0.5
V
Input Leakage Current
-1
1
µA
Threshold Voltage
2.325 2.4 2.475 V
VIN SENSE PIN
Input Leakage Current
-1
1
µA
Threshold Voltage
2.325 2.4 2.475 V
Hysteresis
110
mV
VOUT_OVB, VIN_OVB PIN
Leakage Current
Low Voltage
POWER-GOOD MONITOR PIN
VPIN= HIGH
IPIN = 0.5mA
1
µA
0.2
V
PGOOD Leakage Current
PGOOD = HIGH
1
µA
PGOOD Low Voltage
Overvoltage Rising Trip Point
Overvoltage Rising Hysteresis
Undervoltage Rising Trip Point
Undervoltage Rising Hysteresis
OVER-TEMPERATURE PROTECTION
IPGOOD = 0.5mA
VFB/VREF, VREF2 > 2.5V
VFB/VREF, VREF2 > 2.5V
VFB/VREF, VREF2 > 2.5V
VFB/VREF, VREF2 > 2.5V
0.2
V
117 120 123 %
5
%
77
80
83
%
5
%
Over-Temperature Trip Point
160
°C
Over-Temperature Recovery Threshold
145
°C
NOTES:
6. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise noted. Compliance to datasheet limits is assured by one or
more methods: production test, characterization and/or design.
7. Please refer to LDO current derating curve in “Internal 5V LDO Output Current Limit Derating Curves” on page 20 for IMAX vs VIN.
8. Ts = switching period = 1/(switching frequency).
9
FN7688.0