English
Language : 

HCTS164MS_02 Datasheet, PDF (8/8 Pages) Intersil Corporation – Radiation Hardened 8-Bit Serial-In/Parallel-Out Shift Register
HCTS164MS
Intersil Space Level Product Flow - MS
Wafer Lot Acceptance, All Lots (including SEM);
Method 5007
Gamma Radiation Verification, Each Wafer, 4 Samples/
Wafer, 0 Rejects, Method 1019
100% Nondestructive Bond Pull, Method 2023
Sample Wire Bond Pull Monitor, Method 2011
Sample Die Shear Monitor, Method 2019 or 2027
100% Internal Visual Inspection - Method 2010, Condition A
100% Temperature Cycling, Method 1010, Condition C,
10 Cycles
100% Constant Acceleration Method 2001, Condition per
Method 5004
100% PIND, Method 2020, Condition A
100% External Visual
100% Serialization
100% Initial Electrical Test (T0)
100% Static Burn-In 1, Method 1015, Condition A or B,
24 Hours Minimum, +125oC minimum
100% Interim Electrical Test (T1)
100% Delta Calculation (T0-T1)
100% Static Burn-In 2, Method 1015, Condition A or B, 24
Hours Minimum, + 125oC Minimum
100% Interim Electrical Test 2 (T2)
100% Delta Calculation (T0-T2)
100% PDA 1, Method 5004 (see Notes 1, 2)
100% Dynamic Burn-In, Condition D, 240 Hours, +125oC or
Equivalent per Method 1015
100% Interim Electrical Test 3 (T3)
100% Delta Calculation (T0-T3)
100% PDA 2, Method 5004 (see Note 2)
100% Final Electrical Test
100% Fine/Gross Leak, Method 1014
100% Radiographic, Method 2012 (see Note 3)
100% External Visual, Method 2009
Sample Group A, Method 5005 (see Note 4)
100% Data Package Generation (see Note 5)
NOTES:
1. Failures from Interim Electrical Test 1 and 2 are combined for determining PDA 1.
2. Failures from subgroups 1, 7, 9 and deltas are used for calculating PDA. The maximum allowable PDA = 5% with no more than 3% of the
failures from subgroup 7.
3. Radiographic (X-Ray) inspection may be performed at any point after serialization as allowed by Method 5004.
4. Alternate Group A as allowed by MIL-STD-883, Method 5005 may be performed.
5. Data package contains:
• Cover Sheet (Intersil name and/or logo, PO #, customer part #, lot date code, Intersil part #, lot #, quantity).
• Wafer lot acceptance report (Method 5007). Includes reproductions of SEM photos with % step coverage. GAMMA Radiation Report. Con-
tains cover page, disposition, rad dose, Lot #, test package used, specifications #s, test equipment, etc. radiation read and record data on
file at Intersil.
• X- Ray report and film. Includes pentrameter measurements.
• Screening, electrical, and group A attributes (screening attributes begin after package seal).
• Lot serial number sheet (good units serial # and lot #).
• Variables data (all delta operations). Data is identified by serial number. The data header includes lot # and date of test.
• The Certification of Conformance is part of the shipping invoice and is not part of the data book. The Certificate of Conformance is signed
by an authorized quality representative.
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
Sales Office Headquarters
NORTH AMERICA
Intersil Corporation
7585 Irvine Center Drive
Suite 100
Irvine, CA 92618
TEL: (949) 341-7000
FAX: (949) 341-7123
Intersil Corporation
2401 Palm Bay Rd.
Palm Bay, FL 32905
TEL: (321) 724-7000
FAX: (321) 724-7946
EUROPE
Intersil Europe Sarl
Ave. William Graisse, 3
1006 Lausanne
Switzerland
TEL: +41 21 6140560
FAX: +41 21 6140579
ASIA
Intersil Corporation
Unit 1804 18/F Guangdong Water Building
83 Austin Road
TST, Kowloon Hong Kong
TEL: +852 2723 6339
FAX: +852 2730 1433
Spec Number 518613