HC-5509B_03 Datasheet, PDF (8/9 Pages) Intersil Corporation – ITU CO/Loop Carrier SLIC | |||
|
◁ |
Typical Applications
HC-5509B
5V
5V
RS1 CS1
K1
K2
K1A
TIP
RB1
RB2
SECONDARY
PROTECTION
(NOTE 8)
VB-
C5
PRIMARY
PROTECTION
KIB
RS2
CS2
RING
RB3
VRING
RB4
150VPEAK (MAX)
PTC
Z1
SYSTEM CONTROLLER
SHD GKD PRI RS TEST F1 ALARM F0
RD
PR
TIP
ILIMIT
VRX+
VFB
RF
RFS
SLIC
HC-5509B
VTX
-IN1
OUT1
RING
VB-
BG C2 DG AG
VB+ C1
C3
C4
5V
RL2
RL1
CAC
KRF
KZ0
FROM PCM
FILTER/CODER
TO HYBRID
BALANCE
NETWORK
FIGURE 1. TYPICAL LINE CIRCUIT APPLICATION WITH THE MONOLITHIC SLIC
Typical Component Values
C1 = 0.5µF, 30V.
C2 = 1.0µF ±10%, 20V (for other values of C2 , refer to
AN9667).
C3 = 0.01µF, 100V, ±20%.
C4 = 0.01µF, 100V, ±20%.
C5 = 0.01µF, 100V, ±20%.
CAC = 0.5µF, 20V.
KZ0 = 60kâ¦, (Z0 = 600â¦, K = Scaling Factor = 100).
RL1 , RL2 ; Current Limit Setting Resistors:
RL1 + RL2 > 90k⦠â offset.
ILIMIT = (0.6) (RL1 + RL2)/(200 x RL2), RL1 typically 100kâ¦.
KRF = 20kâ¦, RF = 2(RB2 + RB4), K = Scaling Factor = 100).
RB1 = RB2 = RB3 = RB4 = 50⦠(1% absolute, matching
requirements covered in a Tech Brief).
RS1 = RS2 = 1k⦠, typically.
CS1 = CS2 = 0.1µF, 200V typically, depending on VRing and
line length.
Z1 = 150V to 200V transient protector. PTC used as ring
generator ballast.
8
|
▷ |