English
Language : 

HC-5509B_03 Datasheet, PDF (7/9 Pages) Intersil Corporation – ITU CO/Loop Carrier SLIC
HC-5509B
Overvoltage Protection and Longitudinal
Current Protection
The SLIC device, in conjunction with an external protection
bridge, will withstand high voltage lightning surges and
power line crosses.
High voltage surge conditions are as specified in Table 1.
The SLIC will withstand longitudinal currents up to a
maximum or 30mARMS , 15mARMS per leg, without any
performance degradation.
Logic Diagram
TABLE 1.
PERFORMANCE
PARAMETER TEST CONDITION
(MAX)
UNITS
Longitudinal
Surge
10µs Rise/
1000µs Fall
±1000 (Plastic)
VPEAK
Metallic Surge 10µs Rise/
1000µs Fall
±1000 (Plastic)
VPEAK
T/GND, R/GND 10µs Rise/
1000µs Fall
±1000 (Plastic)
VPEAK
50/60Hz Current
T/GND,
R/GND
11 Cycles,
700 (Plastic)
Limited to 10ARMS
VRMS
RS
TTL TO I2L
RELAY
DRIVER
RD
TTL TO I2L
F0
GK
TTL TO I2L
F1
PD
SH
THERMAL
SHUT DOWN
I2L TO TTL
GKD
I2L TO TTL
SHD
I2L TO TTL
ALM
TTL TO I2L
TEST
THERMAL
SHUT
DOWN
LATCH
7
TO BIAS
NETWORK
INJ
A
A
B
B
C
C
KEY