English
Language : 

X9241A_06 Datasheet, PDF (7/16 Pages) Intersil Corporation – Quad Digital Controlled Potentionmeters (XDCP™)
X9241A
TABLE 1. INSTRUCTION SET
INSTRUCTION FORMAT
INSTRUCTION I3 I2 I1 I0 P1
P0 R1 R0
OPERATION
Read WCR
1 0 0 1 1/0(10) 1/0 X(11) X Read the contents of the Wiper Counter Register pointed to by P1 - P0
Write WCR
1 0 1 0 1/0 1/0 X
X Write new value to the Wiper Counter Register pointed to by P1 - P0
Read Data
Register
1 0 1 1 1/0 1/0 1/0 1/0 Read the contents of the Register pointed to by P1 - P0 and R1 - R0
Write Data
Register
1 1 0 0 1/0 1/0 1/0 1/0 Write new value to the Register pointed to by P1 - P0 and R1 - R0
XFR Data
1 1 0 1 1/0 1/0 1/0 1/0 Transfer the contents of the Register pointed to by P1 - P0 and R1 - R0
Register to WCR
to its associated WCR
XFR WCR to
Data Register
1 1 1 0 1/0 1/0 1/0 1/0 Transfer the contents of the WCR pointed to by P1 - P0 to the Register
pointed to by R1 - R0
Global XFR
0001 X
Data Register to
WCR
X 1/0 1/0 Transfer the contents of the Data Registers pointed to by R1 - R0 of all
four pots to their respective WCR
Global XFR
WCR to Data
Register
1000 X
X 1/0 1/0 Transfer the contents of all WCRs to their respective data Registers
pointed to by R1 - R0 of all four pots
Increment/
Decrement
Wiper
0 0 1 0 1/0 1/0 X
X Enable Increment/decrement of the WCR pointed to by P1 - P0
Notes: (10) 1/0 = data is one or zero
(11) X = Not applicable or don’t care; that is, a data register is not involved in the operation and need not be addressed (typical)
SCL from
Master
1
Data Output
from Transmitter
8
9
Data Output
from Receiver
START
FIGURE 7. ACKNOWLEDGE RESPONSE FROM RECEIVER
Acknowledge
7
FN8164.5
December 14, 2006